Carboxen®-1010 PLOT Capillary GC Column

Carboxen®-1010 PLOT Capillary GC Column

L × I.D. 30 m × 0.53 mm, average thickness 30 μm

Sinonimo/i:

Carboxen® 1010 PLOT Column, 30m x 0.53mm

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

1 EA
1.300,00 €

1.300,00 €


Spedizione prevista il18 marzo 2025Dettagli



Scegli un formato

Cambia visualizzazione
1 EA
1.300,00 €

About This Item

Numero CE:
Codice UNSPSC:
41115710
eCl@ss:
32119290

1.300,00 €


Spedizione prevista il18 marzo 2025Dettagli


Materiali

fused silica

Livello qualitativo

agenzia

ASTM® D3612-96

Descrizione

PLOT = Porous Layer Open Tubular

Produttore/marchio commerciale

Carboxen®

Parametri

≤25-250 °C temperature (isothermal or programmed)

Spessore medio

30 μm

df

30 μm

tecniche

gas chromatography (GC): suitable

Lungh. × D.I.

30 m × 0.53 mm

Gruppo funzionale matrice

Carbon molecular sieve phase

applicazioni

chemicals and industrial polymers
food and beverages

Tipo di colonna

capillary PLOT

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

Application: This column is ideal for the separation of all major components in permanent gas (helium, hydrogen, oxygen, nitrogen, carbon monoxide, methane, and carbon dioxide) and light hydrocarbons (C2-C3) in the same analysis. It is the only column commercially available that is able to separate all major components in permanent gas. This column can also separate oxygen from nitrogen at subambient temperatures.
USP Code: None
Phase:
  • Carbon molecular sieve
Temp. Limits:
  • Subambient to 250 °C (isothermal or programmed)
Carboxen® Adsorbent is ideally used for solid-phase microextraction (SPME)[1] and does highly efficient extraction of small polar molecules from aqueous solution.[2] Porous-layer open-tubular (PLOT) columns are a powerful tool employed in gas chromatography during analysis of fixed gases, light hydrocarbons and volatile solvents. They are mostly preferred over traditional packed columns.[3]

Altre note

We offer a variety of chromatography accessories including analytical syringes

Note legali

ASTM is a registered trademark of American Society for Testing and Materials
Carboxen is a registered trademark of Merck KGaA, Darmstadt, Germany

Applicazioni

N° Catalogo
Descrizione
Determinazione del prezzo

Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Applications of Solid Phase Microextraction
Pawliszyn J.
Applications of Solid Phase Microextraction, 64-65 (1999)
Porous layer open-tubular capillary columns: preparations, applications and future directions.
Zhenghua Ji
Journal of Chromatography A, 842 (1), 115-142 (1999)
Frank Sporkert et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 772(1), 45-51 (2002-05-23)
A new and in part automated headspace solid-phase microextraction method for quantitative determination of the highly toxic rodenticide fluoroacetic acid (FAA) in serum and other biological samples has been developed. FAA and deuterated acetic acid (internal standard) were extracted from
B D Page et al.
Journal of chromatography. A, 873(1), 79-94 (2000-04-11)
The headspace solid-phase microextraction (HS-SPME) efficiencies from vegetable oil of the recently available Carboxen-poly(dimethylsiloxane) (PDMS) and divinylbenzene-Carboxen-PDMS fibres were found to be much greater than those of the PDMS fibre for a number of volatile contaminants. Using these Carboxen-based fibres
Dawn M Chapman et al.
Journal of agricultural and food chemistry, 52(17), 5431-5435 (2004-08-19)
A rapid and automated solid phase microextraction (SPME) stable isotope dilution gas chromatography/mass spectrometry (GC-MS) method for 2-methoxy-3-isobutylpyrazine (MIBP) quantification in red wine was developed. Wines with 30% (w/v) NaCl and 2-methoxy-(2)H(3)-3-isobutylpyrazine internal standard were sampled with a 2 cm

Domande

1–7 di 7 domande  
  1. What are the specific functional groups that may affect the separation and the carbon saturated/unsaturated ratio of the material used in the Carboxen 1010 PLOT capillary column?

    1 risposta
    1. The material used in the Carboxen 1010 PLOT capillary column does not retain any functional groups after the synthesis process due to the high temperatures involved. The carbon surface consists mainly of carbon and hydrogen, with very few exceptions.

      Utile?

  2. Are there specific installation instructions available for the Carboxen-1010 plot column 24246, particularly regarding whether it needs to be baked out before use?

    1 risposta
    1. The installation of capillary columns can differ based on the gas chromatography brand, detector type, injection port, and insertion distance. It's advisable to consult the GC manual for column insertion distance information and any special adapters required before installation.

      Utile?

  3. How can I purchase a column that is packed with this material?

    1 risposta
    1. Most packed column are custom made and require that you obtain a quotation. Please contact our Customer & Sales Services group at phone number (800)-247-6628, fax number (800)-447-3044 or email [email protected] for additional information.

      Utile?

  4. What is the film thickness of the Carboxen™-1010 PLOT Capillary GC Column, Product 25467?

    1 risposta
    1. The film thickness for this column is 30um.  The term "film" is somewhat of a misnomer because it is actually a layer of solid carboxen particles adhered to the fused silica tubing.

      Utile?

  5. Is the Carboxen 1010 PLOT column, Product 25467, GC/MS compatible?

    1 risposta
    1. Yes, the particles are very strongly adhered to the surface of the column and would be compatible with mass spec detection.

      Utile?

  6. What is the Department of Transportation shipping information for this product?

    1 risposta
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Utile?

  7. What types of compounds would be suitable for analysis on the Carboxen™-1010 PLOT Capillary GC Column, Product 25467?

    1 risposta
    1. This column is designed for the analysis of permanent gases and light hydrocarbons up to a maximum of 3 carbon units.

      Utile?

Recensioni

Filtri attivi

  1. Sydney, Australia
    • Recensione 1
    • Voti 0
    5 su 5 stelle.

    Carboxen®-1010 PLOT Capillary GC Column

    Having used another similar column (different manufacturer) for the separation of H2, CO, CO2 and ethylene, I find this column to exhibit very good stability and reliability. Certainly, the high operational temperature rating is most welcomed.

    Traduci con Google

    Utile?

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.