Ugrás a tartalomra
Merck
Összes fotó(1)

Fontos dokumentumok

95636

Supelco

Extractables and Leachables Screening Standard for LC

certified reference material, TraceCERT®, 21 components in acetonitrile, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Bejelentkezésa Szervezeti és Szerződéses árazás megtekintéséhez


About This Item

UNSPSC kód:
41116107
NACRES:
NA.24

grade

certified reference material
TraceCERT®

Minőségi szint

minőség

21 components in acetonitrile

eltarthatósági idő

limited shelf life, expiry date on the label

gyártó/kereskedő neve

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

koncentráció

50 mg/L each component (nominal concentration)

alkalmazás(ok)

pharmaceutical

Formátum

multi-component solution

tárolási hőmérséklet

−20°C

Általános leírás

This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to the SI through a primary reference material from an NMI, e.g. NIST, NRC or NMIJ.
Certified content incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com.

Check out our complete range of extractables and leachables certified reference mixes

Alkalmazás

The certified reference material (CRM) is intended to be used as a calibrant for Extractables and Leachables testing in various plastic compounds.

Certified Reference Mixtures in ExtractablesScreening of Polymeric Materials: For Container–Closure Systems and Single-UseEquipment (article in bioprocess international )

Extractables Study with LC-UV/MS - Efficient identification and quantification of unknownextractables of a single-use system using the certified reference material(CRM) mix for extractables and leachables article from AnalytixReporter issue 12


Tulajdonságok és előnyök

  • Produced and certified under ISO/IEC 17025 and ISO 17034 accreditation
  • Traceable to certified NIST SRMs
  • Accompanied with a comprehensive Certificate of Analysis (CoA) (up to four pages), following ISO Guide 31, with data on stability, density, homogeneity, the accuracy of concentration, uncertainty, and traceability
  • Gravimetrically prepared using high-quality qNMR-characterized starting materials and qualified precision balances to ensure minimal uncertainty
  • Rigorously tested through real-time stability studies to ensure accuracy and shelf life
  • Available in well-sealed amber glass ampules

Elkészítési megjegyzés

For the preparation of this CRM only materials of highest purity were used.

Jogi információk

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Analit

Leírás

    Pentaerythritol tetrakis(3,5-di-tert-butyl-4-hydroxyhydrocinnamate)
    Octadecyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate
    2-(2-Hydroxy-5-methylphenyl)benzotriazole
    ε-Caprolactam
    Dibenzylamine
    Benzoic acid
    2-Mercaptobenzothiazole
    Bisphenol A
    2-Ethylhexanoic acid
    Bis(4-chlorophenyl) sulfone
    3,5-Di-tert-butyl-4-hydroxybenzyl alcohol
    2,6-Di-tert-butyl-4-methylphenol
    1,3-Di-tert-butylbenzene
    Oleamide
    Bis(2-ethylhexyl) phthalate
    Stearic acid
    cis-13-Docosenoamide
    Tris(3,5-di-tert-butyl-4-hydroxybenzyl) isocyanurate
    Tris(2,4-di-tert-butylphenyl)phosphate
    2,4-Di-tert-butylphenol
    Palmitic acid
    Összes mutatása (21)

Piktogramok

FlameExclamation mark

Figyelmeztetés

Danger

Figyelmeztető mondatok

Veszélyességi osztályok

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

Tárolási osztály kódja

3 - Flammable liquids

WGK

WGK 2

Lobbanási pont (F)

42.8 °F - closed cup

Lobbanási pont (C)

6.0 °C - closed cup


Analitikai tanúsítványok (COA)

Analitikai tanúsítványok (COA) keresése a termék sarzs-/tételszámának megadásával. A sarzs- és tételszámok a termék címkéjén találhatók, a „Lot” vagy „Batch” szavak után.

Már rendelkezik ezzel a termékkel?

Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.

Dokumentumtár megtekintése

Az ügyfelek ezeket is megtekintették

Cikkek

Ascentis® C18 column facilitates LC-UV/MS analysis of extractables from single-use systems, ensuring reliable identification and quantification.

Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.

Lépjen kapcsolatba a szaktanácsadással