Ugrás a tartalomra
Merck

427772

Sigma-Aldrich

Polyethylene

average Mw ~4,000 by GPC, average Mn ~1,700 by GPC

Szinonimák:

PE

Bejelentkezésa Szervezeti és Szerződéses árazás megtekintéséhez


About This Item

Lineáris képlet:
H(CH2CH2)nH
CAS-szám:
MDL-szám:
UNSPSC kód:
12162002
PubChem Substance ID:
NACRES:
NA.23

form

powder

Minőségi szint

molekulatömeg

average Mn ~1,700 by GPC
average Mw ~4,000 by GPC

viszkozitás

1.5 poise(25 °C, Brookfield Thermosel)(lit.)

mp

92 °C

savszám

<0.05 mg KOH/g

átmeneti hőmérséklet

softening point 106 °C (ring and ball)

sűrűség

0.92 g/mL at 25 °C

InChI

1S/C2H4/c1-2/h1-2H2

Nemzetközi kémiai azonosító kulcs

VGGSQFUCUMXWEO-UHFFFAOYSA-N

Looking for similar products? Látogasson el ide Útmutató a termékösszehasonlításhoz

Alkalmazás

Mold release additive, lubricant in rubber processing, extrusion and calendering aid for PVC and dispersing aid for color concentrates.PEG-4000 may be used as a precipitant during protein fractionation and virus precipitation.Influence of PEG of various molecular weights on mammalian cell hybridization.

Tulajdonságok és előnyök

Low molecular weight and viscosity for easy processing.

Tárolási osztály kódja

11 - Combustible Solids

WGK

WGK 3

Lobbanási pont (F)

Not applicable

Lobbanási pont (C)

Not applicable

Egyéni védőeszköz

Eyeshields, Gloves, type N95 (US)


Válasszon a legfrissebb verziók közül:

Analitikai tanúsítványok (COA)

Lot/Batch Number

Nem találja a megfelelő verziót?

Ha egy adott verzióra van szüksége, a tétel- vagy cikkszám alapján rákereshet egy adott tanúsítványra.

Már rendelkezik ezzel a termékkel?

Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.

Dokumentumtár megtekintése

Az ügyfelek ezeket is megtekintették

A method for the estimation of polyethylene glycol in plasma protein fractions, Analytical Biochemistry
Sims GEC and Snape TJ
Analytical Biochemistry, 107(1), 60-63 (1980)
Reduced cortical neurotransmitPolyethylene glycol-induced mammalian cell hybridization: Effect of polyethylene glycol molecular weight and concentration.
Davidson RL, et al.
Somatic Cell Genetics, 2(3), 271-280 (1976)
Frederick J Kummer et al.
Journal of long-term effects of medical implants, 22(2), 177-179 (2013-02-23)
A polyethylene cup explanted after 41 years was examined using several analytical techniques to determine whether there was a material cause for the extremely low wear observed. Neither the amount of polyethylene oxidation nor crystallinity appeared to be a factor.
Lisa K McCarthy et al.
Pediatrics, 132(1), e135-e141 (2013-06-19)
Hypothermia on admission to the NICU is associated with increased mortality in preterm infants. Many newborns are hypothermic on admission despite using polyethylene bags (PBs). Using exothermic mattresses (EMs) in addition to PBs may reduce hypothermia but increase hyperthermia. We
Melody Yee-Man Wong et al.
Rapid communications in mass spectrometry : RCM, 27(6), 713-721 (2013-02-19)
Despite various porous materials having been widely adopted as spraying tips for direct sample analysis using electrospray ionization mass spectrometry (ESI-MS), the effect of surface property and porosity of spraying tip materials on their analytical performances is not clear. Investigation

Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.

Lépjen kapcsolatba a szaktanácsadással