Přejít k obsahu
Merck
Všechny fotografie(2)

Hlavní dokumenty

1.03728

Supelco

Water

suitable for UHPLC, LiChrosolv®

Synonyma:

DI water, Deionized water

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Lineární vzorec:
H2O
Číslo CAS:
Molekulová hmotnost:
18.02
Beilstein/REAXYS Number:
2050024
MDL number:
UNSPSC Code:
41104213
NACRES:
NA.03
technique(s):
UHPLC: suitable
application(s):
general analytical
bp:
100 °C (lit.)
vapor pressure:
23 hPa ( 20 °C)

Název produktu

Water, for UHPLC-MS LiChrosolv®

agency

suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1621
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA 8327
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for EPA OTM-45
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
suitable for ISO 25101
suitable for ISO/CEN 15968-2010
suitable for SM 4500 - NH3

Quality Level

reg. compliance

suitable for FDA C-010.02

vapor pressure

23 hPa ( 20 °C)

product line

LiChrosolv®

form

liquid

technique(s)

UHPLC: suitable

refractive index

n20/D 1.34 (lit.)

pH

7 (20 °C)

bp

100 °C (lit.)

mp

0 °C (lit.)
0.0 °C (32.0 °F)

solubility

water: miscible

density

1.000 g/mL at 3.98 °C (lit.)

cation traces

Al: ≤5 ppb
Ca: ≤5 ppb
Fe: ≤5 ppb
K: ≤5 ppb
Mg: ≤10 ppb
Na: ≤50 ppb

application(s)

general analytical

storage temp.

2-30°C

SMILES string

O

InChI

1S/H2O/h1H2

InChI key

XLYOFNOQVPJJNP-UHFFFAOYSA-N

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

General description

LiChrosolv® solvents exhibit high degree of UV transmittance, low particle count, low acidity and alkalinity and low evaporation residue level. This makes them ideal for reproducible separations.

Features and Benefits

  • suitability tested and specified for UHPLC-MS and UHPLC-UV: for analytical flexibility
  • specified quality in positive and negative in positive and negative electrospray ionization (ESI) and atmospheric-pressure chemical ionization-mass spectrometry (APCI-MS) for lowest detection limits and confidence in analyses for all important MS modes (test 1)
    —ESI/APCI (+) < 2 ppb
    —ESI/APCI (-) < 10 ppb
  • lowest impurity profile: for interference-free baselines (test 2)
  • microfiltered through 0.2 μm filter (test 3) to provide:
    —a long lifespan to filters and mechanical parts of HPLC systems
    —reduced risk of column clogging
  • packed in borosilicate glass bottles for minimized metal ion contaminations
  • lowest levels of trace metal impurities for a minimum metal ion adduct formation
    —<5 ppb
  • lowest level of polyethylene glycol (PEG) impurities in UHPLC-MS solvent lineup (PEG S/N signal-to-noise-ratio < 50)

Other Notes

Explore various lab safety accessories and equipment for safe handling of solvents to increase your safety level from the first usage.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
LICHROSOLV is a registered trademark of Merck KGaA, Darmstadt, Germany

accessory

Č. produktu
Popis
Stanovení ceny

Storage Class

12 - Non Combustible Liquids

wgk_germany

nwg

flash_point_f

No data available

flash_point_c

No data available


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Zákazníci si také prohlíželi

Slide 1 of 5

1 of 5

Water ACS reagent, for ultratrace analysis

Supelco

14211

Water

Water for analysis EMSURE&#174;

Supelco

1.16754

Water

Methanol hypergrade for LC-MS LiChrosolv&#174;

Supelco

1.06035

Methanol

Methanol UHPLC, suitable for mass spectrometry (MS)

Sigma-Aldrich

900688

Methanol

Acetonitrile hypergrade for LC-MS LiChrosolv&#174;

Supelco

1.00029

Acetonitrile

Sortimentní položky

We present a fast and robust HPLC-MS/MS method that can be used for Remdesivir and three structural antiviral analogues

Extract pantothenic acid (vitamin B5) from infant formula and quantify via LC-MS/MS using Ascentis® Express C18 UHPLC column per GB 5009.210-2023.

Learn how filter selection and sample and mobile phase filtration impact HPLC back pressure and column lifetime.

A precise U/HPLC-MS/MS method with QuEChERS extraction for the analysis of glyphosate, glufosinate, and AMPA in green tea.

Zobrazit všechny

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.