1.16754
Water
suitable for UV/Vis spectroscopy, EMSURE®
Synonyma:
DI water, Deionized water
About This Item
Doporučené produkty
product name
Water, for analysis EMSURE®
vapor pressure
23 hPa ( 20 °C)
Quality Level
product line
EMSURE®
form
liquid
technique(s)
UV/Vis spectroscopy: suitable
impurities
≤0.01 mg/L Ammonium (NH4)
≤0.01 mg/L Nitrate (NO3)
≤0.01 mg/L Phosphate (PO4)
≤0.01 mg/L Silicate (SiO2)
≤0.05 mg/L Chloride (Cl)
≤0.05 mg/L Fluoride (F)
≤0.08 mg/L Substances reducing potassium permanganate (O)
≤0.1 mg/L Sulfate (SO4)
evapn. residue
≤1 mg/L
ign. residue
≤1 mg/L
refractive index
n20/D 1.34 (lit.)
pH
7 (20 °C)
bp
100 °C (lit.)
mp
0 °C (lit.)
density
1.000 g/mL at 3.98 °C (lit.)
cation traces
Ag: ≤0.0004 mg/L
Al: ≤0.0020 mg/L
As: ≤0.0020 mg/L
Au: ≤0.0010 mg/L
B: ≤0.0050 mg/L
Ba: ≤0.0010 mg/L
Be: ≤0.0020 mg/L
Bi: ≤0.0010 mg/L
Ca: ≤0.0050 mg/L
Cd: ≤0.0010 mg/L
Co: ≤0.0010 mg/L
Cr: ≤0.0004 mg/L
Cu: ≤0.0004 mg/L
Fe: ≤0.0010 mg/L
Ga: ≤0.0040 mg/L
Ge: ≤0.0010 mg/L
In: ≤0.0010 mg/L
K: ≤0.0050 mg/L
Li: ≤0.0020 mg/L
Mg: ≤0.0050 mg/L
Mn: ≤0.0004 mg/L
Mo: ≤0.0020 mg/L
Na: ≤0.0100 mg/L
Ni: ≤0.0004 mg/L
Pb: ≤0.0010 mg/L
Pd: ≤0.0080 mg/L
Pt: ≤0.0010 mg/L
Sb: ≤0.0010 mg/L
Sn: ≤0.0010 mg/L
Sr: ≤0.0004 mg/L
Ti: ≤0.0010 mg/L
V: ≤0.0010 mg/L
Zn: ≤0.0040 mg/L
Zr: ≤0.0010 mg/L
SMILES string
O
storage temp.
15-25°C
InChI
1S/H2O/h1H2
InChI key
XLYOFNOQVPJJNP-UHFFFAOYSA-N
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
General description
Application
- Cadmium Standard for Atomic Absorption Spectroscopy: An article in Heliyon (2024) explores the pollution indices and correlation of heavy metal contamination, including cadmium, in groundwater near industrial sites. This emphasizes the role of cadmium AAS standards in monitoring environmental pollution and ensuring compliance with safety regulations (Mohan et al., 2024).
- Trace Metal Analysis in Food Samples: In a Food Chemistry study (2024), cadmium standards are crucial for the development of novel electrochemical strategies for detecting cadmium in grain and water, using advanced materials like MXene@rGO composite aerogels (Dong et al., 2023).
- Quality Control in Pharmaceutical Research: The need for precise cadmium calibration standards is underlined in another Food Chemistry publication (2024), which discusses simultaneous electrochemical sensing of heavy metals in food, demonstrating their vital role in ensuring the accuracy and reliability of pharmaceutical and biotechnological analyses (Mirzaei Karazan et al., 2024).
Analysis Note
Evaporation residue: ≤ 1 mg/l
Residue on ignition: ≤ 1 mg/l
Chloride (Cl): ≤ 0.05 mg/l
Fluoride (F): ≤ 0.05 mg/l
Nitrate (NO₃): ≤ 0.01 mg/l
Phosphate (PO₄): ≤ 0.01 mg/l
Sulfate (SO₄): ≤ 0.1 mg/l
Silicate (SiO₂): ≤ 0.01 mg/l
Ammonium (NH₄): ≤ 0.01 mg/l
Ag (Silver): ≤ 0.0004 mg/l
As (Arsenic): ≤ 0.0020 mg/l
Al (Aluminium): ≤ 0.0020 mg/l
Au (Gold): ≤ 0.0010 mg/l
B (Boron): ≤ 0.0050 mg/l
Ba (Barium): ≤ 0.0010 mg/l
Be (Beryllium): ≤ 0.0020 mg/l
Bi (Bismuth): ≤ 0.0010 mg/l
Ca (Calcium): ≤ 0.0050 mg/l
Cd (Cadmium): ≤ 0.0010 mg/l
Co (Cobalt): ≤ 0.0010 mg/l
Cr (Chromium): ≤ 0.0004 mg/l
Cu (Copper): ≤ 0.0004 mg/l
Fe (Iron): ≤ 0.0010 mg/l
Ga (Gallium): ≤ 0.0040 mg/l
Ge (Germanium): ≤ 0.0010 mg/l
In (Indium): ≤ 0.0010 mg/l
K (Potassium): ≤ 0.0050 mg/l
Li (Lithium): ≤ 0.0020 mg/l
Mg (Magnesium): ≤ 0.0050 mg/l
Mn (Manganese): ≤ 0.0004 mg/l
Mo (Molybdenum): ≤ 0.0020 mg/l
Na (Sodium): ≤ 0.0100 mg/l
Ni (Nickel): ≤ 0.0004 mg/l
Pb (Lead): ≤ 0.0010 mg/l
Pd (Palladium): ≤ 0.0080 mg/l
Pt (Platinum): ≤ 0.0010 mg/l
Sb (Antimony): ≤ 0.0010 mg/l
Sn (Tin): ≤ 0.0010 mg/l
Sr (Strontium): ≤ 0.0004 mg/l
Ti (Titanium): ≤ 0.0010 mg/l
V (Vanadium): ≤ 0.0010 mg/l
Zn (Zinc): ≤ 0.0040 mg/l
Zr (Zirconium): ≤ 0.0010 mg/l
Substances reducing potassium permanganate (O): ≤ 0.08 mg/l
Legal Information
Storage Class
12 - Non Combustible Liquids
wgk_germany
nwg
flash_point_f
Not applicable
flash_point_c
Not applicable
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Sortimentní položky
Preparation of a standard solution for COD/chloride
Spectroquant® photometric test accurately quantifies low concentrations of PO4-P in natural waters.
Application Note: Peroxidase in vegetables – Visual determination after conversion of a specific substrate.
Protokoly
Analytical Method: Iodine in table salt
Hydroxymethylfurfural (HMF) in honey – reflectometric determination after after conversion with a barbituric acid derivative and an aminophenazone derivative
Preparation of a standard solution for Chlorine dioxide acc. to DIN EN ISO 7393
Preparation of a standard solution for Sulfide
Související obsah
Learn about the sample preparation and photometric determination of non-ionic surfactants in Extran® rinse solutions (MA 01, MA 02, MA 05, AP 22) using Spectroquant® test kits and spectrophotometers.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..