1.03701
Hexane
≥99% (GC), suitable for LC/MS, LiChrosolv®
Synonyma:
Hexane, n-Hexane
About This Item
Doporučené produkty
product name
n-Hexane, hypergrade for LC-MS LiChrosolv®
vapor density
~3 (vs air)
Quality Level
vapor pressure
256 mmHg ( 37.7 °C)
5.2 psi ( 37.7 °C)
~132 mmHg ( 20 °C)
product line
LiChrosolv®
assay
≥99% (GC)
form
liquid
autoignition temp.
453 °F
expl. lim.
7.7 %
technique(s)
LC/MS: suitable
impurities
≤0.0002 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.005% Water
≤10 ppb Al (Aluminium)
≤10 ppb Ca (Calcium)
≤10 ppb Fe (Iron)
≤10 ppb Mg (Magnesium)
≤10 ppb Na (Sodium)
≤5 ppb K (Potassium)
evapn. residue
≤2.0 mg/L
transmittance
210 nm, ≥60%
225 nm, ≥90%
245 nm, ≥98%
refractive index
n20/D 1.375 (lit.)
kinematic viscosity
0.50 cSt(20 °C)
bp
69 °C (lit.)
mp
−95 °C (lit.)
transition temp
flash point -22 °C
density
0.659 g/mL at 25 °C (lit.)
storage temp.
2-30°C
SMILES string
CCCCCC
InChI
1S/C6H14/c1-3-5-6-4-2/h3-6H2,1-2H3
InChI key
VLKZOEOYAKHREP-UHFFFAOYSA-N
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
Související kategorie
General description
Application
Also used in:
- analysis of mineral oil saturated hydrocarbons in vegetable oils by LC-GC interface.
- studies on sugars and organic acids in biological matrices using GC coupled to triple quadruple mass spectrometry (QqQ-MS).
Features and Benefits
- no ghost peaks
- full reproducibility
- extends the lifetime of columns
- optimized and tested for LC-MS applications
- minimal background ion suppression
- reduced risk of contamination
- less exposure to hazardous chemicals
Preparation Note
Analysis Note
Identity (IR): conforms
Evaporation residue: ≤ 2.0 mg/l
Water: ≤ 0.005 %
Acidity: ≤ 0.0002 meq/g
Alkalinity: ≤ 0.0002 meq/g
Al (Aluminium): ≤ 10 ppb
Ca (Calcium): ≤ 10 ppb
Fe (Iron): ≤ 10 ppb
K (Potassium): ≤ 5 ppb
Mg (Magnesium): ≤ 10 ppb
Na (Sodium): ≤ 10 ppb
Transmission (at 210 nm): ≥ 60 %
Transmission (at 225 nm): ≥ 90 %
Transmission (from 245 nm): ≥ 98 %
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI positive): ≤ 2 ppb
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI negative): ≤ 20 ppb
Filtered by 0,2 µm filter.
Other Notes
Legal Information
related product
signalword
Danger
Hazard Classifications
Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3
target_organs
Central nervous system, Nervous system
Storage Class
3 - Flammable liquids
wgk_germany
WGK 3
flash_point_f
-7.6 °F
flash_point_c
-22 °C
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Sortimentní položky
Nonylphenols (NP) are ubiquitous substances that have been detected in highly diverse foodstuff. As breakdown products of nonylphenol ethoxylates, NP could end up in the aquatic environment. This article presents a rapid method for NP detection in surface water by planar solid phase extraction – planar yeast estrogen screen (pSPE-pYES).
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.