1.59014
Acetonitrile solution
suitable for LC/MS, LiChrosolv®, contains 0.1% (v/v) trifluoroacetic acid
Synonyma:
Acetonitrile solution, ACN, ACN + TFA, Cyanomethane, Ethyl nitrile, Methyl cyanide
About This Item
Doporučené produkty
Název produktu
Acetonitrile with 0.1% (v:v) trifluoroacetic acid, hypergrade for LC-MS LiChrosolv®
vapor pressure
97 hPa ( 20 °C)
Quality Level
product line
LiChrosolv®
form
liquid
concentration
0.095-0.105 % (v/v)
technique(s)
LC/MS: suitable
impurities
≤0.025 ppm K (Potassium)
≤0.05 ppm Al (Aluminium)
≤0.05 ppm Ca (Calcium)
≤0.05 ppm Fe (Iron)
≤0.05 ppm Mg (Magnesium)
≤0.25 ppm Na (Sodium)
color
APHA: ≤10
transition temp
flash point 2 °C
density
0.782 g/mL at 25 °C
format
mixture
storage temp.
2-30°C
SMILES string
CC#N
InChI
1S/C2H3N/c1-2-3/h1H3
InChI key
WEVYAHXRMPXWCK-UHFFFAOYSA-N
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
Související kategorie
Application
- Retention time prediction for post-translationally modified peptides: Ser, Thr, Tyr-phosphorylation.: This study presents a methodology for predicting retention times of phosphorylated peptides using high-performance liquid chromatography (HPLC) (Battellino et al., 2024).
- Development and validation of a UPLC-PDA method for quantifying ceftazidime in dried blood spots.: This paper outlines a validated ultra-performance liquid chromatography photodiode array (UPLC-PDA) method for the quantification of ceftazidime, demonstrating its application and accuracy in analyzing dried blood samples (Lv et al., 2024).
- A facile fabric phase sorptive extraction method for monitoring chloramphenicol residues in milk samples.: Describes a new method using fabric phase sorptive extraction for the efficient monitoring of chloramphenicol in milk, highlighting its simplicity and effectiveness (Ben Ayed et al., 2024).
- Study of sample preparation influence on bacterial lipids profile in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.: This research investigates how different sample preparation methods affect the lipid profiles of bacteria analyzed by MALDI-TOF MS, providing insights into optimizing protocols for better accuracy (Arendowski et al., 2024).
- Simple and robust LC-MS/MS method for quantification of colistin methanesulfonate and colistin in human plasma for therapeutic drug monitoring.: This article details a robust and straightforward liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of colistin methanesulfonate and colistin in human plasma, useful in clinical settings (Kim et al., 2023).
Preparation Note
Analysis Note
Identity: passes test
Color: ≤ 10 Hazen
Al (Aluminium): ≤ 0.05 ppm
Ca (Calcium): ≤ 0.05 ppm
Fe (Iron): ≤ 0.05 ppm
K (Potassium): ≤ 0.025 ppm
Mg (Magnesium): ≤ 0.05 ppm
Na (Sodium): ≤ 0.25 ppm
Gradient grade (at 210 nm): ≤ 1.0 mAU
Gradient grade (at 254 nm): ≤ 0.5 mAU
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI positive): ≤ 2 ppb
Filtered by 0.2 µm filter.
Other Notes
Legal Information
related product
signalword
Danger
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class
3 - Flammable liquids
wgk_germany
WGK 2
flash_point_f
35.6 °F - (Acetonitrile)
flash_point_c
2 °C - (Acetonitrile)
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Sortimentní položky
Determination of plasma protein binding using a SupelTM C18 pin device based BioSPME method for efficient sample preparation, along with a comparison to the equilibrium dialysis method.
Learn the tips and tricks of selecting and preparing a suitable mobile phase buffer for your HPLC separations and method developments for samples that contain ionizable compounds.
The application note describes a comparative analysis of plasma protein binding results for free/bound drugs using two different sample extraction steps, with and without agitation.
Learn about Supel™ BioSPME C18 high-throughput devices to determine plasma protein binding and decrease the sample preparation time to less than an hour.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.