Direkt zum Inhalt
Merck
  • Determination of polyphenolic compounds in Cirsium palustre (L.) extracts by high performance liquid chromatography with chemiluminescence detection.

Determination of polyphenolic compounds in Cirsium palustre (L.) extracts by high performance liquid chromatography with chemiluminescence detection.

Talanta (2014-12-02)
Edyta Nalewajko-Sieliwoniuk, Julita Malejko, Monika Mozolewska, Elżbieta Wołyniec, Jolanta Nazaruk
ZUSAMMENFASSUNG

The first method for the simultaneous determination of polyphenolic antioxidants in extracts from leaves of Cirsium palustre based on high performance liquid chromatography combined with flow injection chemiluminescence detection (HPLC-FI-CL) has been developed. The extracts were prepared by using methanol as extraction medium and two types of extraction methods (reflux and ultrasound assisted extraction). The post-column CL determination of polyphenols was based on their enhancing effect on the chemiluminescence intensity generated in manganese(IV)-hexametaphosphate-formaldehyde system in a phosphoric acid medium. Main antioxidants determined in C. palustre leaves were eriodictyol-7-O-glucoside, luteolin-7-O-glucoside and 6-hydroxyluteolin-7-O-glucoside belonging to flavonoids, and chlorogenic acid belonging to phenolic acids. Chromatographic separation was carried out on a C18 column with gradient elution by using a mobile phase containing 0.25% (v/v) phosphoric acid in water (solvent A) and 100% methanol (solvent B). Under the optimized conditions of chromatographic separation and CL detection the validation of the method was performed. The calibration curves showed good linearity in the concentration range from 0.5 to 40 µg mL(-1). The HPLC-FI-CL method was successfully applied to the determination of four polyphenolic compounds in methanolic extracts from leaves of C. palustre. The accuracy of the developed method was confirmed by the comparison of the results with those obtained by an HPLC-PDA method. The relative error of determination does not exceed 6.1%. However, the HPLC-FI-CL method is characterized by 40-65 times higher sensitivity compared to the HPLC-PDA method.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Essigsäure, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acetonitril, HPLC Plus, ≥99.9%
Sigma-Aldrich
Natriumhydroxid, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Essigsäure, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Natriumhydroxid, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Natronlauge, 50% in H2O
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetonitril, ACS reagent, ≥99.5%
Sigma-Aldrich
Natronlauge, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
Acetonitril, ≥99.9% (GC)
Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Essigsäure, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Essigsäure, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
Natriumhydroxid, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
Natriumhydroxid, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
Natronlauge, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Essigsäure, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
Essigsäure -Lösung, suitable for HPLC
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Natriumhydroxid, reagent grade, 97%, powder
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Mangan(IV)-oxid, ReagentPlus®, ≥99%
Sigma-Aldrich
Natriumhydroxid, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
Natriumhydroxid, puriss. p.a., ACS reagent, reag. Ph. Eur., K ≤0.02%, ≥98%, pellets
Sigma-Aldrich
Natriumformiat, ACS reagent, ≥99.0%