Direkt zum Inhalt
Merck

P6407

Sigma-Aldrich

Poly-ᴅ-Lysine Hydrobromide

synthetic, mol wt 70,000-150,000, powder, γ-irradiated, suitable for cell culture, BioXtra

Synonym(e):

PDL

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

5 MG
CHF 137.00
10 X 5 MG
CHF 637.00

CHF 137.00


Voraussichtliches Versanddatum30. März 2025


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
5 MG
CHF 137.00
10 X 5 MG
CHF 637.00

About This Item

Lineare Formel:
D-Lys-(D-Lys)n-D-Lys · xHBr
CAS-Nummer:
MDL-Nummer:
UNSPSC-Code:
12352202
PubChem Substanz-ID:
NACRES:
NA.75

CHF 137.00


Voraussichtliches Versanddatum30. März 2025


Bulk-Bestellung anfordern

Produktbezeichnung

Poly-D-Lysin -hydrobromid, mol wt 70,000-150,000, lyophilized powder, γ-irradiated, BioReagent, suitable for cell culture

Biologische Quelle

synthetic (organic)

Qualitätsniveau

Sterilität

γ-irradiated

Produktlinie

BioReagent
BioXtra

Form

lyophilized powder

Mol-Gew.

70,000-150,000

Verpackung

pkg of 10 X 5 mg
pkg of 5 mg

Konzentration

0.016—0.032 mmol lysine

Methode(n)

cell culture | mammalian: suitable

Oberflächendeckung

4 μg/cm2

Verunreinigungen

<10% water (by Karl Fischer)

Löslichkeit

H2O: soluble 50 mg/mL, clear, colorless

Versandbedingung

ambient

Lagertemp.

−20°C

SMILES String

O=C(C)[C@@](NC)([H])CCCCN.[Br]

InChI

1S/C6H14N2O2.BrH/c7-4-2-1-3-5(8)6(9)10;/h5H,1-4,7-8H2,(H,9,10);1H

InChIKey

MEXAGTSTSPYCEP-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Anwendung

Anwendungsgebiete von Poly-D-Lysin-Hydrobromid:

  • Als Beschichtung für Platten bei der Kultivierung von Glia-Vorläuferzellen aus Ratten (RGPCS)[1]
  • Zur Beschichtung von Flaschen und Platten bei der Kultivierung von Tanyzyten[2]
  • Zur Vorbereitung der Oberfläche von Deckgläsern zur Erleichterung der Zellanhaftung[3]
Poly-D-Lysin-Polymere können zur Vorbereitung von Oberflächen für die Zellhaftung verwendet werden. Die D-Lysin-Polymere können auch mit Zellen verwendet werden, die Poly-L-Lysin-Polymere aufschließen und eine übermäßige Aufnahme von L-Lysin verursachen.

Dieses Produkt wird zur Verwendung als Trägerschicht (Substratum) in der Zellkultur empfohlen, wenn 0,5–1,0 ml einer 0,1 mg/ml Lösung zur Beschichtung von 25 cm2 verwendet werden. Produktausführungen mit niedrigerer Molekülmasse sind weniger viskos, Ausführungen mit einer höheren Molekülmasse bieten jedoch mehr Bindungsstellen pro Molekül.

Biochem./physiol. Wirkung

Poly-D-Lysin(PDL)-Hydrobromid ist ein unspezifischer Bindungsfaktor für Zellen und erhöht die Zelladhäsion an festen Substraten, indem es die elektrostatische Wechselwirkung zwischen negativ geladenen Ionen der Zellmembran und der Kulturoberfläche verstärkt. Nach der Absorption an die Kulturoberfläche erhöht Poly-D-Lysin die Anzahl der positiv geladenen Zellbindungsstellen.

Leistungsmerkmale und Vorteile

  • Mit Gammastrahlung (γ) sterilisiert.
  • Sterile Poly-D-Lysin-Lösungen können bei 2–8 ˚C drei Jahre lang gelagert werden.

Komponenten

Poly-D-Lysin ist ein positiv geladenes Aminosäurepolymer mit etwa einem HBr pro Lysin-Rest. Das Hydrobromid ermöglicht die kristalline, wasserlösliche Form des Poly-D-Lysins. Eine geringe Produktmenge kann in der ß-Struktur vorliegen, da das HBr die Wasserstoffbindung zwischen Aminogruppen und den Carboxylgruppen oder N oder O enthaltenden Einheiten beeinträchtigt.

Vorsicht

Sterile Lösungen sind bei Lagerung zwischen 2 und 8 °C bis zu 2 Jahre haltbar. Sie sollten bei -20 °C aufbewahrt werden.

Angaben zur Herstellung

Dieses Produkt hat ein Molekulargewicht von 70.000-150.000 und ist zellkulturgetestet und gammabestrahlt. Zur Entfernung der HBr lösen Sie das Produkt in einem neutralen Puffer und dialysieren es, um die Salze zu entfernen. Um dieses Produkt als Bindungsfaktor zu verwenden, geben Sie 50 ml steriles Wasser für Gewebekulturen zu 5 mg Polylysin und beschichten die Oberfläche unter aseptischen Bedingungen mit 1 ml Lösung pro 25 cm2. Nach 5 Minuten entfernen Sie die Lösung durch Aspiration und spülen die Oberfläche gründlich ab. Lassen Sie die Oberfläche zwei Stunden trocknen, bevor Sie Zellen und Medium aufbringen.

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Gloves, type N95 (US)


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Paclitaxel is effective for controlling astrocyte proliferation in vitro: Implications for generating ventral mesencephalic cultures enriched with dopamine neurons
Galvez and Gates MA
Journal of Neuroscience Methods (2020)
Yunze Yang et al.
ACS nano, 12(5), 4186-4193 (2018-03-24)
Action potentials in neurons have been studied traditionally by intracellular electrophysiological recordings and more recently by the fluorescence detection methods. Here we describe a label-free optical imaging method that can measure mechanical motion in single cells with a sub-nanometer detection
Tania Massignan et al.
Scientific reports, 6, 23180-23180 (2016-03-16)
Prion diseases are rare neurodegenerative conditions associated with the conformational conversion of the cellular prion protein (PrP(C)) into PrP(Sc), a self-replicating isoform (prion) that accumulates in the central nervous system of affected individuals. The structure of PrP(Sc) is poorly defined
Charles Van der Henst et al.
Nature communications, 9(1), 3460-3460 (2018-08-29)
Vibrio cholerae, which causes the diarrheal disease cholera, is a species of bacteria commonly found in aquatic habitats. Within such environments, the bacterium must defend itself against predatory protozoan grazers. Amoebae are prominent grazers, with Acanthamoeba castellanii being one of
Thibaut Brunet et al.
Science (New York, N.Y.), 366(6463), 326-334 (2019-10-19)
Collective cell contractions that generate global tissue deformations are a signature feature of animal movement and morphogenesis. However, the origin of collective contractility in animals remains unclear. While surveying the Caribbean island of Curaçao for choanoflagellates, the closest living relatives

Artikel

Poly-Lysine enhances cell binding with positively-charged surface ions, optimizing electrostatic interaction on culture surfaces for increased cell attachment.

Cancer stem cell media, spheroid plates and cancer stem cell markers to culture and characterize CSC populations.

Protokolle

Adhere cells to solid substrates using poly-lysine, which enhances electrostatic interaction between negatively charged ions of the cell membrane and the culture surface.

Anhaften von Zellen an festen Substraten mit Hilfe von Polylysin, das die elektrostatische Wechselwirkung zwischen negativ geladenen Ionen der Zellmembran und der Kulturoberfläche verstärkt.

Questions

1–10 of 11 Questions  
  1. 이 가루는 3차 증류수에 녹이면 될까요? 녹인 PDL은 -20에 보관하면 되나요?

    1 answer
    1. This product is tested for solubility in water at 50 mg/mL. The product, in solution, is quite stable when stored at 2-8°C. The freeze/thaw stability of this material has not been investigated. However, the thawing process may cause degradation. The product P4832 is a prepared solution that is stored refrigerated and assigned a 2 year shelf life.

      Please see the link below to review the product datasheet for additional information:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/784/704/p6407pis.pdf

      Helpful?

  2. Comparitively which is better to use with Human embryonic kidney cells, P6407 or P2636?

    1 answer
    1. Comparison testing of these products on Human embryonic kidney cells has not been conducted. In general, P6407 is preferred due to the fact that P2636, provided in L form, is more susceptible to degradation by proteases secreted by cell lines compared to the d-form polymer provided in P6407.

      Helpful?

  3. Is there a standard method of determining the quality of the coating? (Particular focus should be placed on ensuring that the cells adhere as evenly as possible)

    1 answer
    1. As mentioned on the product detail page, this product is recommended as a cell culture substratum when using 0.5 - 1.0 mL of a 0.1 mg/mL solution to coat 25 cm2. Lower molecular weight versions of the product are less viscous, but high molecular weight versions provide more attachment sites per molecule.

      For more information on using this product for quality coating, please read through the product information sheet:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/784/704/p6407pis.pdf

      Helpful?

  4. Do you have a protocol for coating cell cultureware or glass coverslips/slides with Product P6407, Poly-D-Lysine?

    1 answer
    1. The protocol for coating surfaces with poly-D-lysine is the same as for poly-L-lysine.  The optimal conditions must be determined for each cell line and application. In general, the following steps can be used.1. Add 50 ml of sterile tissue culture grade water to 5 mg of poly-D-lysine.2. Aseptically coat culture surface with 0.5-1.0 ml of solution per 25 cm2. Rock gently to ensure even coating of the culture surface.3. After 5 minutes, remove solution by aspiration and thoroughly rinse surface with sterile tissue culture grade water.4. Allow to dry at least two hours before introducing cells and medium.

      Helpful?

  5. How long can I store poly-lysine coated slides or plates?

    1 answer
    1. Plates and/or slides can be stored after drying, protected from dust for up to 1 year.  Inspect the plates/slides to make sure there are no cracks in the coating prior to use.  Each lab should determine the maximum length of time for storage based on the application.

      Helpful?

  6. Does Product P6407, Poly-D-lysine hydrobromide, need to be dialyzed to remove the hydrogen bromide?

    1 answer
    1. The hydrogen bromide will not interfere with the cell growth.  The hydrogen bromide salts are used to make our poly-L-lysine solutions that are cell culture tested.  For these products, there is no interference in cell growth from the bromide.

      Helpful?

  7. Why would I use Product P6407, Poly-D-lysine hydrobromide, instead of poly-L-lysine?

    1 answer
    1. Certain cells can digest poly-L-lysine, in which case the poly-D-lysine should be used.

      Helpful?

  8. How do I determine which molecular weight range of poly-lysine to use?

    1 answer
    1. Poly-lysine is used to coat surfaces to increase the charge present. The lower molecular weight poly-L-lysine (30-70 kD) is easier to use because it is less viscous in solution, but the higher molecular weight poly-L-lysine (>300 kD) provides more attachment sites per molecule. The mid-range product has a molecular weight range of 70-150 kD.  Please check the literature for information on the molecular weight range used for your cell type.

      Helpful?

  9. How should I store solutions of poly-lysine?

    1 answer
    1. Poly-lysine solutions (0.1 to 1 mg/ml) can be sterile-filtered (0.2 um) and should be stored at 2-8 °C.  Solutions should not be stored frozen as thawing can cause a decrease in the size (molecular weight range) of the polymer.

      Helpful?

  10. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

1–10 of 11 Questions  

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.