  • Parallel analysis of volatile fatty acids, indole, skatole, phenol, and trimethylamine from waste-related source environments.

Parallel analysis of volatile fatty acids, indole, skatole, phenol, and trimethylamine from waste-related source environments.

Journal of chromatography. A (2013-09-28)
Md Mahmudur Rahman, Ki-Hyun Kim
RESUMO

An experimental technique based on sorbent tube-thermal desorption-gas chromatography (ST-TD-GC) was investigated for the simultaneous determination of a cluster of eight volatile odorants (propionic acid, n-butyric acid, i-valeric acid, n-valeric acid, trimethylamine, phenol, indole, and skatole) and a reference compound (benzene). Calibration was made by direct injection of a liquid working standard (L-WS) into a quartz tube packed with three bed sorbent (Tenax TA, Carbopack B, and Carbopack X). To assess the relative performance between different detector systems, a comparative analysis was made using both mass spectrometry (MS) and a flame ionization detector (FID) with the aid of a TD system. In the TD-GC-MS analysis, calibration results were evaluated in two different modes, namely total ion chromatogram (TIC) and extracted ion chromatogram (EIC). In both FID and MS, the elution order of investigated odorants complied with the retention time index (RTI) values for the polar column with a coefficient of determination (R(2)) at or above 0.99. As a means to validate our detection approach, environmental samples from a bathroom and manhole (vacuum samples) as well as cat stool and wastewater (headspace samples) were also collected. The ST-TD method tested for the concurrent analysis of diverse odorants allowed us to measure a list of offensive odorants from those samples.

MATERIAIS
Número do produto
Marca
Descrição do produto

Sigma-Aldrich
Fenol, BioReagent, Equilibrated with 10 mM Tris HCl, pH 8.0, 1 mM EDTA, for molecular biology
Sigma-Aldrich
Fenol, BioReagent, Saturated with 0.01 M citrate buffer, pH 4.3 ± 0.2, for molecular biology
Sigma-Aldrich
Fenol, ≥99%
Sigma-Aldrich
Trimetilamina, 43.0-49.0% in H2O (T)
Sigma-Aldrich
Trimethylamine hydrochloride, 98%
Sigma-Aldrich
Trimetilamina, 31-35 wt. % in ethanol, 4.2 M, contains toluene as stabilizer
Supelco
FLM Carbopack X Deactivated Stainless Steel TD Tube, preconditioned, pkg of 10 tubes, O.D. × L 1/4 in. (6.35 mm) × 3 1/2 in. (89 mm)
Supelco
Fenol, certified reference material, 500 μg/mL in methanol
Sigma-Aldrich
Trimetilamina, 25 wt. % in H2O
Sigma-Aldrich
3-Methylindole, 98%
Sigma-Aldrich
Fenol, BioUltra, for molecular biology, TE-saturated, ~73% (T)
Supelco
Fenol, 5000 μg/mL in methanol, certified reference material
Sigma-Aldrich
Skatole, ≥98%
Supelco
Adsorvente Carbopack, matrix Carbopack B, 60-80 mesh, bottle of 10 g
Sigma-Aldrich
Fenol, puriss. p.a., ACS reagent, reag. Ph. Eur., 99.0-100.5%
Sigma-Aldrich
Fenol, ≥89.0%
Sigma-Aldrich
Fenol, for molecular biology
Supelco
Adsorvente Carbopack, matrix Carbopack C, 60-80 mesh, bottle of 10 g
Supelco
Adsorvente Carbopack, matrix Carbopack C, 80-100 mesh, bottle of 10 g
Supelco
Adsorvente Carbopack, matrix Carbopack X, 40-60 mesh, bottle of 10 g
Supelco
Carbopack B, O.D. × L 1/4 in. × 3 1/2 in., glass TD tube, fritted, Sealed with Brass Endcaps, preconditioned, pkg of 10 ea
Supelco
Fenol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Fenol, BioXtra, ≥99.5% (GC)
Sigma-Aldrich
Fenol, puriss., ≥99.5% (GC), meets analytical specification of Ph. Eur., BP, USP, crystalline (detached)
Sigma-Aldrich
Fenol, contains hypophosphorous as stabilizer, loose crystals, ACS reagent, ≥99.0%
Supelco
Adsorvente Carbopack, matrix Carbopack X, 60-80 mesh, bottle of 10 g
Sigma-Aldrich
Fenol, unstabilized, ReagentPlus®, ≥99%
Supelco
Fenol, PESTANAL®, analytical standard
Supelco
Adsorvente Carbopack, matrix Carbopack X, 120-400 mesh, bottle of 50 g
Sigma-Aldrich
Fenol, ≥96.0% (calc. on dry substance, T)