Pular para o conteúdo
Merck

A new approach for diffusive sampling based on SPME for occupational exposure assessment.

Journal of occupational and environmental hygiene (2013-01-30)
P Marín, J F Periago, C Prado
RESUMO

Passive sampling is a well-established methodology for the evaluation of exposures to environmental volatile organic compounds (VOCs). The solid-phase microextraction (SPME) technique is a reliable means of sampling VOCs in air. SPME is also being applied as a passive sampler to determine time-weighted average exposure. The use of SPME as a diffusive sampler was evaluated. The passive sampler is based on the use of a cylindrical diffusion cell (porous hydrophobic polyethylene) with an 80 μm carboxen/polydimethylsiloxane fiber to obtain radial diffusion of the analytes to the sorbent. Standard atmospheres of organic vapors in air were used to determine the experimental uptake rates for toluene and chlorobenzene. Toluene concentrations between 2 and 38 mg/m(3) with sampling times between 15 and 60 min were evaluated, as well as chlorobenzene concentrations between 2 and 47 mg/m(3) with sampling times between 30 and 60 min. The mean diffusive uptake rate was 2.14 mL/min for toluene and 2.57 mL/min for chlorobenzene, and no statistical significant effects of concentration and sampling time were observed under the studied conditions for the two compounds. Relative standard deviation ranged from 2.6 to 6.5%. The performance of the sampler under varying concentrations of toluene was also tested, showing that the sampler reflects the average exposure concentration. Effects of temperature, relative humidity, velocity of the air, back diffusion, competitive adsorption, and the stability of chlorobenzene in the sampler were also studied. Sampler behavior was tested in gas stations, and the results were successfully compared with a 3M-3500 diffusive sampler. The results are promising for using this new SPME device for diffusive monitoring for occupational exposure assessment.

MATERIAIS
Número do produto
Marca
Descrição do produto

Sigma-Aldrich
Tolueno, ACS reagent, ≥99.5%
Sigma-Aldrich
Tolueno, suitable for HPLC, 99.9%
Sigma-Aldrich
Tolueno, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Chlorobenzene, ReagentPlus®, 99%
Sigma-Aldrich
Tolueno, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.7% (GC)
Sigma-Aldrich
Tolueno, anhydrous, 99.8%
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Sigma-Aldrich
Chlorobenzene, ACS reagent, ≥99.5%
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Sigma-Aldrich
Chlorobenzene, suitable for HPLC, 99.9%
Supelco
ORBO 90 Carboxen® 564 (20/45), 160/80 mg, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Sigma-Aldrich
Tolueno, ACS reagent, ≥99.5%
Sigma-Aldrich
Chlorobenzene, anhydrous, 99.8%
Sigma-Aldrich
Tolueno, Laboratory Reagent, ≥99.3%
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Adsorvente Carboxen®, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
ORBO 78 HBr on Carboxen® 564 specially cleaned (20/45), 400/200 mg, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea
Supelco
Coluna de GC capilar Carboxen®-1006 PLOT, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Toluene solution, certified reference material, 5000 μg/mL in methanol
Supelco
Tolueno, analytical standard
Supelco
Tolueno, Pharmaceutical Secondary Standard; Certified Reference Material