Glucose Colorimetric/Fluorometric Assay Kit

sufficient for 100 colorimetric or fluorometric tests

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
12161503
NACRES:
NA.84

zastosowanie

sufficient for 100 colorimetric or fluorometric tests

Zastosowanie

cosmetics
food and beverages

metoda wykrywania

colorimetric
fluorometric

powiązane choroby

endocrinological disorders, diabetes

temp. przechowywania

−20°C

Opis ogólny

Glucose is a primary energy source that naturally occurs in its free state in fruits and other plant parts. Abnormal glucose levels have been associated with several metabolic dysfunctions such as hypoglycemia, hyperglycemia, and diabetes mellitus. Measurements of glucose levels in tissues and body fluids (such as blood and urine) are often used for the diagnosis of glucose– related disorders. Glucose levels are also monitored to check the efficacy of therapeutics such as insulin and sulphonylureas in type 2 diabetics.

Cechy i korzyści

Compatible with high-throughput handling systems.

Przydatność

Suitable for the determination of glucose concentrations in various biological samples, including serum, plasma, food, or growth medium. This kit is also suitable for monitoring glucose levels during fermentation and glucose feeding in protein expression processes.

Zasada

Glucose is oxidized to generate a colorimetric (570 nm)/ fluorometric (λex = 535/λem = 587 nm) product, proportional to the amount of glucose present. The kit is able to detect 1-10,000 μM of glucose in various samples.
Ta strona może zawierać tekst przetłumaczony maszynowo.

Piktogramy

Health hazard

Hasło ostrzegawcze

Danger

Zwroty wskazujące rodzaj zagrożenia

Zwroty wskazujące środki ostrożności

Klasyfikacja zagrożeń

Aquatic Chronic 3 - Resp. Sens. 1

Kod klasy składowania

10 - Combustible liquids

Temperatura zapłonu (°F)

Not applicable

Temperatura zapłonu (°C)

Not applicable


Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Daniela Scribano et al.
Molecules (Basel, Switzerland), 25(2) (2020-01-17)
Urinary tract infections (UTIs) are mainly caused by uropathogenic Escherichia coli (UPEC). Acute and recurrent UTIs are commonly treated with antibiotics, the efficacy of which is limited by the emergence of antibiotic resistant strains. The natural sugar d-mannose is considered
Mike Boger et al.
Frontiers in cell and developmental biology, 10, 918529-918529 (2022-07-26)
The ELMO protein family consists of the homologues ELMO1, ELMO2 and ELMO3. Several studies have shown that the individual ELMO proteins are involved in a variety of cellular and developmental processes. However, it has poorly been understood whether the Elmo
Gemma K Kinsella et al.
International journal of molecular sciences, 22(19) (2021-10-14)
GPR21 is a constitutively active, orphan, G-protein-coupled receptor, with in vivo studies suggesting its involvement in the modulation of insulin sensitivity. However, its precise contribution is not fully understood. As the liver is both a major target of insulin signalling
Ryan K Perkins et al.
Nutrients, 11(3) (2019-03-03)
The purpose of this investigation was to evaluate the effects of experimental hyperglycemia on oxidative damage (OX), advanced glycation end products (AGEs), and the receptor for AGEs (RAGE) through an in vivo approach. Obese subjects (n = 10; 31.2 ±
Ye Du et al.
Frontiers in oncology, 10, 580176-580176 (2021-01-05)
Hypoxia is an important environmental factor and has been correlated with tumor progression, treatment resistance and poor prognosis in many solid tumors, including triple-negative breast cancer (TNBC). Emerging evidence suggests that long noncoding RNA (lncRNA) functions as a critical regulator

Questions

1–2 of 2 Questions  
  1. Can this kit be used on solid tissue samples? If so, how should the tissue be homogenized?

    1 answer
    1. This kit can be used for tissue samples. To homogenize, please proceed as follows:
      Homogenize the tissue sample in assay buffer using the following protocol:

      Start with approximately 10 mg of tissue (the amount may need to be optimized), wash in cold PBS and resuspend in ~100 uL of assay buffer provided with the kit.
      Homogenize using a Dounce homogenizer or a pestle, on ice to keep the sample cold (10-15 passes).
      Centrifuge at 4°C in a cold microcentrifuge to remove insoluble.
      Collect the supernatant and keep it on ice throughout sample preparation.

      Use a few different volumes of this supernatant (between 2 and 50 uL) and bring them up to a total volume of 50 µl/well with Glucose Assay Buffer in a 96-well plate, as recommended for a typical liquid sample.
      The reason for trying different volumes of samples is to ensure the readings are within the standard curve range.
      Then proceed with the 'Assay Reaction' step.

      Please see the datasheet below for the assay reaction step:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/275/602/mak263bul.pdf

      Helpful?

  2. We require a protocol for #MAK263 for my customer

    1 answer
    1. Helpful?

Reviews

No rating value

Active Filters

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej