コンテンツへスキップ
Merck

Thermo-responsive adsorbent for size-selective protein adsorption.

Journal of chromatography. A (2015-04-04)
Micky Fu Xiang Lee, Eng Seng Chan, Kam Chiu Tam, Beng Ti Tey
要旨

A thermo-responsive random copolymer, POEGMA (poly(oligoethylene glycol) methacrylate) grafted on cationized agarose adsorbent was used for size selective protein adsorption. The effects of OEGMA300 ((oligoethylene glycol) methyl ether methacrylate, Mn=300g/mol) content and temperature on the adsorption of bovine serum albumin (BSA) were evaluated. Increasing the content of OEGMA300 resulted a reduction in BSA adsorption due to the enhanced shielding effect of OEGMA300 chains. Grafting of POEGMA chains onto cationized agarose adsorbent reduced the BSA adsorption by more than 95% at 26.5°C, which is below the LCST (lower critical solution temperature) of POEGMA. The BSA adsorption capacities for adsorbents grafted with 10 and 20mol% of OEGMA300 decreased by 48% and 46% respectively at 38°C, a temperature higher than their LCSTs. The temperature-dependent adsorption of BSA on the adsorbents was attributed to changes in the polymer conformation. The thermal transition of grafted POEGMA conformation exposed the ligand when the temperature was increased. Myoglobin (Myo), which was smaller than BSA, its adsorption behavior was less dependent on the polymer conformation. The adsorption of myoglobin onto the adsorbent with and without POEGMA showed similar percentage of reduction whereas the adsorption of BSA onto the adsorbent with POEGMA decreased by 7.6 times compared to the one without POEGMA. The packed bed of POEGMA grafted adsorbent was used for flow through separation of a protein mixture consisted of virus-like particle, Hepatitis B virus-like particle (HBVLP), BSA and insulin aspart. The recovery of HBVLP in 20mol% of OEGMA300 grafted adsorbent was increased by 19% compared to ungrafted adsorbent. The flow through of BSA can be reduced by increasing the operating temperature above LCST of 20mol% of OEGMA300 while the smaller protein, insulin aspart, remained adsorbed onto the cationized surface. Hence, this thermo-responsive adsorbent has a potential for size-selective separation of protein especially for the recovery of large biomolecule.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
過硫酸アンモニウム, for molecular biology, suitable for electrophoresis, ≥98%
Sigma-Aldrich
塩酸 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
塩酸, 36.5-38.0%, BioReagent, for molecular biology
Supelco
塩酸 溶液, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
塩酸, SAJ first grade, 35.0-37.0%
Sigma-Aldrich
テトラヒドロフラン, anhydrous, ≥99.9%, inhibitor-free
Sigma-Aldrich
塩酸, JIS special grade, 35.0-37.0%
Sigma-Aldrich
塩酸 溶液, 1 M
Sigma-Aldrich
テトラヒドロフラン, anhydrous, contains 250 ppm BHT as inhibitor, ≥99.9%
Sigma-Aldrich
グリシジルトリメチルアンモニウムクロリド, technical, ≥90% (calc. based on dry substance, AT)
Sigma-Aldrich
エチレングリコール, anhydrous, 99.8%
Sigma-Aldrich
塩酸 溶液, ~6 M in H2O, for amino acid analysis
Sigma-Aldrich
過硫酸アンモニウム, BioUltra, for molecular biology, ≥98.0% (RT)
Sigma-Aldrich
塩酸 溶液, 0.1 M
Sigma-Aldrich
塩酸 溶液, 6 M
Sigma-Aldrich
塩酸 溶液, 12 M
Sigma-Aldrich
塩化水素 溶液, 3 M in cyclopentyl methyl ether (CPME)
Sigma-Aldrich
塩酸 溶液, 2 M
Sigma-Aldrich
エチレングリコール 溶液
Sigma-Aldrich
エチレングリコール, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
テトラヒドロフラン, suitable for HPLC, contains no stabilizer
Sigma-Aldrich
塩酸 溶液, 0.5 M
Sigma-Aldrich
テトラヒドロフラン, SAJ first grade, ≥99.0%
Sigma-Aldrich
テトラヒドロフラン, JIS special grade, ≥99.5%
Sigma-Aldrich
アデノシン 5′-ホスホ硫酸 ナトリウム塩, ≥85%
Sigma-Aldrich
塩酸 溶液, 0.2 M
Sigma-Aldrich
過硫酸アンモニウム, BioXtra, ≥98.0%
Sigma-Aldrich
塩酸 溶液, 0.01 M
Supelco
エチレングリコール 溶液, NMR reference standard, 80% in DMSO-d6 (99.9 atom % D), NMR tube size 5 mm × 8 in.
Sigma-Aldrich
塩酸 溶液, 0.05 M