コンテンツへスキップ
Merck
  • Comparing ion-pairing reagents and counter anions for ion-pair reversed-phase liquid chromatography/electrospray ionization mass spectrometry analysis of synthetic oligonucleotides.

Comparing ion-pairing reagents and counter anions for ion-pair reversed-phase liquid chromatography/electrospray ionization mass spectrometry analysis of synthetic oligonucleotides.

Rapid communications in mass spectrometry : RCM (2015-11-14)
Lingzhi Gong
要旨

Ion-pair reversed-phase liquid chromatography/electrospray ionization mass spectrometry (IP-RP-LC/ESI-MS) has been widely used for the quality control of oligonucleotides. However, researchers are still looking to improve mobile phase systems for IP-RP-LC/ESI-MS analysis of oligonucleotides. This study compared the performance of six ion-pairing reagents with three different counter anions for IP-RP-LC/ESI-MS analysis of oligonucleotides. The study was performed using a Waters ultra-performance liquid chromatography (UPLC®) system coupled to a Waters LCT Premier XE mass spectrometer by using a UPLC® OST column (2.1 mm × 100 mm, 1.7 µm). Buffer systems containing acetate, bicarbonate, and hexafluoroisopropanolate salts of six ion-pairing reagents (triethylamine, tripropylamine, hexylamine, N,N-dimethylbutylamine, dibutylamine, N,N-diisopropylethylamine), respectively, were optimized for IP-RP-LC/ESI-MS analysis of oligonucleotides, and then the optimized conditions were applied for the separation of oligonucleotides. Counter anions definitely play a role in IP-RP-LC/ESI-MS analysis of oligonucleotides. Buffer containing 30 mM diisopropylethylamine and 200 mM hexafluoroisopropanol provided the highest separation of unmodified heterogeneous oligonucleotides, but tripropylammonium hexafluoroisopropanolate achieved the most enhanced separation of sequence isomers. However, triethylammonium acetate and bicarbonate had equally the highest separation for positional isomers. IP-RP-LC/ESI-MS separation of oligonucleotides is mainly sequence dependent, but it is also dependent on both the type of ion-pairing reagent and counter anion present in the mobile phase.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
酢酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
酢酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
1,1,1,3,3,3-ヘキサフルオロ-2-プロパノール, ≥99%
Sigma-Aldrich
酢酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
N,N-ジイソプロピルエチルアミン, 99.5%, biotech. grade
Sigma-Aldrich
酢酸 溶液, suitable for HPLC
Sigma-Aldrich
メタノール, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
酢酸, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
メタノール, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
ジブチルアミン, ≥99.5%
Sigma-Aldrich
ヘキシルアミン, 99%
Sigma-Aldrich
メタノール, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
トリエチルアミン, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
メタノール, Absolute - Acetone free
Sigma-Aldrich
メタノール, BioReagent, ≥99.93%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
Sigma-Aldrich
酢酸, for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
トリプロピルアミン, ≥98%
Sigma-Aldrich
酢酸, ≥99.5%, FCC, FG
Sigma-Aldrich
酢酸, natural, ≥99.5%, FG
Sigma-Aldrich
5α-アンドロスタン-17β-オール-3-オン, ≥97.5%
Sigma-Aldrich
メタノール, SAJ first grade, ≥99.5%
Sigma-Aldrich
トリエチルアミン, ≥99.5%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
酢酸, ≥99.7%
Sigma-Aldrich
酢酸, JIS special grade, ≥99.7%
Sigma-Aldrich
トリエチルアミン, ≥99%