Passa al contenuto
Merck

US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on SLB®-5ms, Direct Injection

US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on SLB®-5ms, Direct Injection suitable for GC

Materiali

Accessorio

N° Catalogo
Descrizione
Determinazione del prezzo

Wheaton wide-mouth bottle

amber soda-lime glass bottle, capacity 1000 mL, white polypropylene cap, (PTFE faced LDPE liner), case of 12 ea

Boccole Supeltex M -2B con entrambe le estremità a tronco di cono

I.D. 0.4 mm, 0.10-0.25 mm to like I.D. Column, pkg of 2 ea

Capillary Column Butt Connector

body only (ferrules not included)

Colonna analitica

N° Catalogo
Descrizione
Determinazione del prezzo

Colonna GC capillare SLB®-5ms

L × I.D. 30 m × 0.25 mm, df 0.25 μm

Colonna GC capillare SLB®-5ms

L × I.D. 30 m × 0.25 mm, df 0.50 μm

Colonna GC capillare SLB®-5ms

L × I.D. 30 m × 0.25 mm, df 1.00 μm

Colonna GC capillare SLB®-5ms

L × I.D. 20 m × 0.18 mm, df 0.18 μm

Precolonna

N° Catalogo
Descrizione
Determinazione del prezzo

Intermediate Polar Fused Silica Tubing

L × I.D. 5.0 m × 0.25 mm

Standard

N° Catalogo
Descrizione
Determinazione del prezzo

N-Nitrosodiphenylamine solution

certified reference material, 5000 μg/mL in methanol

Perfluorotributylamine (PFTBA)

analytical standard

EPA 8270 GC-MS Tuning Solution II

certified reference material, 1000 μg/mL each component in dichloromethane

EPA GRO Mix

certified reference material, in methanol (varied)

EPA CLP Semivolatile Calibration Mix

certified reference material, 1000 μg/mL each component in dichloromethane : benzene (3:1)

EPA CLP Semivolatiles Surrogate Standards Mix

certified reference material, 4000 μg/mL each component in methylene chloride

EPA 8270 Semivolatile Internal Standard Mix

certified reference material, TraceCERT®, 2000 μg/mL each component in methylene chloride, ampule of 2 × 1 mL

EPA 8270 Benzidines Mix

certified reference material, TraceCERT®, 2000 μg/mL each component in methanol, ampule of 1 mL

CONDITIONS

column

SLB-5ms, 30 m x 0.25 mm I.D., 1.0 μm (28476-U)

oven

50 °C (3 min), 15 °C/min to 200 °C

inj. temp.

150 °C

detector

FID, 250 °C

carrier gas

helium, 1.3 mL/min., constant

injection

0.5 μL, 50:1 split

liner

2 mm I.D., FocusLiner inlet liner

sample

EPA GRO Mix, 9 analytes at various concentrations in methanol (47577-U)

Descrizione

Note legali

FocusLiner is a trademark of SGE Analytical Science Pty Ltd.
SLB is a registered trademark of Merck KGaA, Darmstadt, Germany