- Determining exhaust fumes exposure in chainsaw operations.
Determining exhaust fumes exposure in chainsaw operations.
Environmental pollution (Barking, Essex : 1987) (2016-09-12)
F Neri, C Foderi, A Laschi, F Fabiano, M Cambi, G Sciarra, M C Aprea, A Cenni, E Marchi
PMID27614911
ABSTRACT
The objective of this study was to investigate the inhalation exposure of forest operators to polycyclic aromatic hydrocarbons (PAHs) and BTEX (benzene, toluene, ethylbenzene and total xylenes) contained in the exhaust fumes released from chainsaws and to suggest possible countermeasures. The study was carried out in four silvicultural treatments (coppice clearcut, conifer thinning, conifer pruning, and sanitary cut), using three types of chainsaw fuel (normal two-stroke petrol mix and two alkylate fuels). Eighty personal air samples were collected; IOM samplers combined with Amberlite XAD-2 sorbent tubes were used for collecting PAHs and Radiello
MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto
Cartucce adsorbenti Radiello™, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
Piastra di supporto triangolare radiello™, pk of 20
Corpi diffusivi Radiello™, white, configured for general use, pk of 20
Cartucce adsorbenti Radiello™, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
Cartucce adsorbenti Radiello™, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
Corpi diffusivi Radiello™, blue, configured for sampling light sensitive compounds, pk of 20
Corpi diffusivi Radiello™, yellow, configured for reduced sampling rates, pk of 20
Cartucce adsorbenti Radiello™, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
radiello™ Methylene Blue Calibration Standard for H2S (Hydrogen Sulfide), pkg of 100 mL
radiello™ Outdoor Shelter, pk of 10
radiello™ Barcode Labels, pk of 198
radiello™ Vertical Adapter, threaded for standard use, pk of 20
radiello™ BTEX/VOC Starter Kit, CS2 Desorption
radiello™ BTEX/VOC Starter Kit, Thermal Desorption
radiello™ Filtration Kit, pk of 20
radiello™ Hydrogen Sulfide Starter Kit
Cartucce adsorbenti Radiello™, for sampling Anaesthetic Gases/Vapors, matrix SS net with mix of mol sieve and activated charcoal (30-50 mesh), pk of 20
radiello™ Anesthetic Gases and Vapor Sampler
radiello™ Empty Storage Tubes, polypropylene (with stopper), volume 12 mL, pk of 100
radiello™ On-Field Thermometer, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
radiello™ Empty Storage Tubes, glass (with stopper), volume 2.8 mL, pk of 100
Supelco
radiello™ Aldehyde Calibration Standard, 50 μg/mL each component in acetonitrile, pkg of 10 mL
radiello™ Clips, suspending Radiello triangular support plate, pk of 20
radiello™ 1,3-Butadiene Starter Kit, Thermal Desorption, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
Corpi diffusivi Radiello™, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello™ On-Field Thermometer, Reader, pk of 1
radiello™ Replacement Mounting Strips, for use with Radiello Outdoor Shelter, pk of 100