  • Quantification of piperacillin, tazobactam, cefepime, meropenem, ciprofloxacin and linezolid in serum using an isotope dilution UHPLC-MS/MS method with semi-automated sample preparation.

Quantification of piperacillin, tazobactam, cefepime, meropenem, ciprofloxacin and linezolid in serum using an isotope dilution UHPLC-MS/MS method with semi-automated sample preparation.

Clinical chemistry and laboratory medicine (2014-10-11)
Johannes Zander, Barbara Maier, Anna Suhr, Michael Zoller, Lorenz Frey, Daniel Teupser, Michael Vogeser
ABSTRACT

Recent studies have demonstrated highly variable blood concentrations of piperacillin, tazobactam, cefepime, meropenem, ciprofloxacin and linezolid in critically ill patients with a high incidence of sub-therapeutic levels. Consequently, therapeutic drug monitoring (TDM) of these antibiotics has to be considered, requiring robust and reliable routine analytical methods. The aim of the present work was to develop and validate a multi-analyte ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for the simultaneous quantification of the above mentioned antibiotics. Sample preparation included a manual protein precipitation step followed by two-dimensional ultra high performance liquid chromatography (2D-UHPLC). Corresponding stable isotope-labeled substances were used as internal standards for all of the analytes, with the exception of tazobactam. The injected sample volume was 7 μL. The run time was 5.0 min. Inaccuracy was ≤8% and imprecision coefficient of variation (CV) was <9% for all analytes. Only minor matrix effects and negligible carry-over was observed. The method was found to be robust during the validation period. We were able to develop a reliable 2D-UHPLC-MS/MS method addressing analytes with highly heterogeneous physico-chemical properties. The novel assay may be an efficient tool for an optimized process workflow in clinical laboratories for important antibiotics in regards to TDM.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Metanolo, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Acido formico, reagent grade, ≥95%
Sigma-Aldrich
Metanolo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acido formico, ACS reagent, ≥96%
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Metanolo, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Acido formico, ACS reagent, ≥88%
Sigma-Aldrich
Metanolo, BioReagent, ≥99.93%
Sigma-Aldrich
Metanolo, Absolute - Acetone free
Sigma-Aldrich
Metanolo, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
USP
Metanolo, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Meropenem trihydrate, ≥98% (HPLC)
Supelco
Metanolo, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Acido formico, ≥95%, FCC, FG
Sigma-Aldrich
Piperacillina, penicillin analog
Supelco
Metanolo, analytical standard
Sigma-Aldrich
Tazobactam sodium salt, β-lactamase inhibitor
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Sigma-Aldrich
Metanolo, NMR reference standard
USP
Piperacillina, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Meropenem trihydrate, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Supelco
Meropenem trihydrate, VETRANAL®, analytical standard
Supelco
Piperacillina, analytical standard
Piperacillina, European Pharmacopoeia (EP) Reference Standard