Passa al contenuto
Merck
  • Coupling of solid phase microextraction with electrospray ionization ion mobility spectrometry and direct analysis of venlafaxine in human urine and plasma.

Coupling of solid phase microextraction with electrospray ionization ion mobility spectrometry and direct analysis of venlafaxine in human urine and plasma.

Analytica chimica acta (2014-12-04)
Mohammad T Jafari, Mohammad Saraji, Amir H Ameri
ABSTRACT

The capability of electrospray ionization-conventional ion mobility spectrometry (ESI-IMS) for direct analysis of the samples extracted by solid phase microextraction (SPME) was investigated and evaluated for the first time. To that end, an appropriate new desorption chamber was designed and constructed, resulting in the possibility of direct exposure of the SPME fiber to the electrospray solvent flow. Two different elution methods in dynamic and static modes were exhaustively investigated. The results indicated that the interface could help us to have an accurate and sensitive analysis without disturbing the electrospray process, in static elution method. Venlafaxine as a test compound was extracted from human urine and plasma by a convenient headspace SPME method. The positive ion mobility spectrum of the extracted drug was obtained and the analyte responses were calculated. The coupled method of SPME-ESI-IMS was comprehensively validated in terms of sensitivity, dynamic range, and recovery percentage. Finally, various real samples of human urine and plasma were analyzed, all verifying the feasibility and success of the proposed method for the easy routine analysis.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Metanolo, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Acido trifluoroacetico, ReagentPlus®, 99%
Sigma-Aldrich
Acido trifluoroacetico, suitable for HPLC, ≥99.0%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Metanolo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Sodio dodecil solfato, BioReagent, suitable for electrophoresis, for molecular biology, ≥98.5% (GC)
Sigma-Aldrich
Acido trifluoroacetico, puriss. p.a., suitable for HPLC, ≥99.0% (GC)
Sigma-Aldrich
Sodio dodecil solfato, ≥99.0% (GC), dust-free pellets
Sigma-Aldrich
tetra-etil ortosilicato, reagent grade, 98%
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Sodio dodecil solfato, BioUltra, for molecular biology, 10% in H2O
Sigma-Aldrich
Metanolo, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
tetra-etil ortosilicato, ≥99.0% (GC)
Sigma-Aldrich
Trichloroacetic acid solution, 6.1 N
Sigma-Aldrich
Acido trifluoroacetico, ≥99%, for protein sequencing
Sigma-Aldrich
Pyrrole, reagent grade, 98%
Sigma-Aldrich
Sodio dodecil solfato, ACS reagent, ≥99.0%
Sigma-Aldrich
Metanolo, BioReagent, ≥99.93%
Sigma-Aldrich
Sodio dodecil solfato, BioUltra, for molecular biology, 20% in H2O
Sigma-Aldrich
Metanolo, Absolute - Acetone free
Sigma-Aldrich
Metanolo, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Acido tricloroacetico, ACS reagent, ≥99.0%
Sigma-Aldrich
Sodio dodecil solfato, ReagentPlus®, ≥98.5% (GC)
Sigma-Aldrich
Sodio dodecil solfato, BioUltra, for molecular biology, ≥99.0% (GC)
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
USP
Metanolo, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
tetra-etil ortosilicato, 99.999% trace metals basis
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Sodio dodecil solfato, dust-free pellets, suitable for electrophoresis, for molecular biology, ≥99.0% (GC)
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga