Összes fotó(1)
Fontos dokumentumok
29688-U
SP®-2560 Capillary GC Column
L × I.D. 200 m × 0.25 mm, df 0.20 μm
Bejelentkezésa Szervezeti és Szerződéses árazás megtekintéséhez
Összes fotó(1)
About This Item
Javasolt termékek
material
fused silica
Minőségi szint
Ügynökség
AOAC® 2012.13,Ce 1-h05,996.06
meets requirements for USP G5
parameter
≤25-250 °C temperature (isothermal or programmed)
Béta-érték
313
df
0.20 μm
technika/technikák
gas chromatography (GC): suitable
H × belső átmérő
200 m × 0.25 mm
mátrix aktív csoport
Non-bonded; poly(biscyanopropyl siloxane) phase
alkalmazás(ok)
agriculture
clinical
food and beverages
oszloptípus
capillary highly polar
Looking for similar products? Látogasson el ide Útmutató a termékösszehasonlításhoz
Általános leírás
Application: This highly polar biscyanopropyl column was specifically designed for detailed separation of geometricpositional (cis/trans) isomers of fatty acid methyl esters (FAMEs). It is extremely effective for FAME isomer applications.
USP Code: This column meets USP G5 requirements.
Phase:
USP Code: This column meets USP G5 requirements.
Phase:
- Non-bonded
- Poly(biscyanopropyl siloxane)
- Subambient to 250 °C (isothermal or programmed)
Jogi információk
AOAC is a registered trademark of AOAC International
SP is a registered trademark of Sigma-Aldrich Co. LLC
Válasszon a legfrissebb verziók közül:
Már rendelkezik ezzel a termékkel?
Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.
Journal of chromatography. A, 1218(3), 545-554 (2010-12-24)
The ionic liquid SLB-IL111 column, available from Supelco Inc., is a novel fused capillary gas chromatography (GC) column capable of providing enhanced separations of fatty acid methyl esters (FAMEs) compared to the highly polar cyanopropyl siloxane columns currently recommended for
Journal of AOAC International, 85(5), 1112-1118 (2002-10-11)
This study examines the effect of the column operating temperature of 100 m SP-2560 and CP-Sil 88 capillary gas chromatographic (GC) columns on the separation of cis- and trans-octadecenoic (18:1) isomers in partially hydrogenated vegetable oils. The overlapping GC peaks
Journal of AOAC International, 78(3), 783-802 (1995-05-01)
An infrared spectrophotometric (IR) method for the determination of total trans unsaturated fatty acid (trans) content and a combined gas-liquid chromatographic/infrared spectrophotometric (GC/IR) method for determination of fatty acid composition of partially hydrogenated vegetable oils (PHVO) were studied collaboratively in
Analytical chemistry, 81(13), 5561-5568 (2009-06-02)
The present research is focused on the evaluation of one 0.10 mm i.d. and two 0.25 mm i.d., ionic liquid (IL) stationary phase [1,9-di(3-vinyl-imidazolium) nonane bis(trifluoromethyl) sulfonyl imidate] columns, with lengths of 12 (the microbore capillary), 30 and 100 m
Journal of chromatography. A, 1100(2), 185-192 (2005-10-21)
The trans isomers of 5,8,11,14,17-eicosapentaenoic acid (EPA) and 4,7,10,13,16,19-docosahexaenoic acid (DHA) methyl esters were prepared by isomerisation with paratoluenesulfinic acid (PTSA) in dioxane. The isomers were fractionated by silver ion liquid chromatography with baseline resolution between the isomers with different
Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.
Lépjen kapcsolatba a szaktanácsadással