Ugrás a tartalomra
Merck
Összes fotó(1)

Fontos dokumentumok

GE17-0618-05

Protein G Sepharose 4 Fast Flow

Cytiva 17-0618-05, pack of 200 mL

Szinonimák:

Fast Flow resin, Antibody purification resin, IgG purification resin

Bejelentkezésa Szervezeti és Szerződéses árazás megtekintéséhez


About This Item

UNSPSC kód:
41106500
NACRES:
NA.56

ligand

recombinant protein G lacking albumin-binding region

kiszerelés

pack of 200 mL

gyártó/kereskedő neve

Cytiva 17-0618-05

tárolási körülmény

(20% Ehtanol)

Mátrix

4% cross-linked agarose

átlagos átmérő

90 μm (d50v)

cleaning in place

2-10

Működési tartomány

3-9

alkalmasság

suitable for bioprocess medium

tárolási hőmérséklet

2-8°C

Általános leírás

Protein G Sepharose 4 Fast Flow is recombinant protein G coupled to Sepharose 4 Fast Flow.

Protein G Sepharose 4 Fast Flow has recombinant protein G immobilized by the cyanogen bromide (CNBr) method to Sepharose 4 Fast Flow. Protein G exhibit binding specificities that complement Protein A media and binds to the Fc region of IgG from a variety of mammalian species. Protein G Sepharose 4 Fast Flow may be used to isolate and purify classes, subclasses and fragments of immunoglobulins from any biological fluid or cell culture medium.

As member of the BioProcess media range, Protein G Sepharose 4 Fast Flow meets industrial demands with security of supply and comprehensive technical and regulatory support.

Tulajdonságok és előnyök

  • Binding specificities that complement Protein A media.
  • Binds a broad range of IgG species and subclasses.
  • Multi-point attachment minimizes ligand leakage.
  • Used in a range of research applications.

Tárolás és stabilitás

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

Analízis megjegyzés

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Jogi információk

Sepharose is a trademark of Cytiva

Piktogramok

Flame

Figyelmeztetés

Warning

Figyelmeztető mondatok

Óvintézkedésre vonatkozó mondatok

Tárolási osztály kódja

3 - Flammable liquids


Válasszon a legfrissebb verziók közül:

Analitikai tanúsítványok (COA)

Lot/Batch Number

Sajnos jelenleg COA nem áll rendelkezésre ehhez a termékhez online.

Ha segítségre van szüksége, lépjen velünk kapcsolatba Vevőszolgálat

Már rendelkezik ezzel a termékkel?

Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.

Dokumentumtár megtekintése

Az ügyfelek ezeket is megtekintették

Monique G P van der Wijst et al.
bioRxiv : the preprint server for biology (2021-03-25)
Type I interferon (IFN-I) neutralizing autoantibodies have been found in some critical COVID-19 patients; however, their prevalence and longitudinal dynamics across the disease severity scale, and functional effects on circulating leukocytes remain unknown. Here, in 284 COVID-19 patients, we found
Kanika Vanshylla et al.
Cell host & microbe, 29(6), 917-929 (2021-05-14)
Understanding antibody-based SARS-CoV-2 immunity is critical for overcoming the COVID-19 pandemic and informing vaccination strategies. We evaluated SARS-CoV-2 antibody dynamics over 10 months in 963 individuals who predominantly experienced mild COVID-19. Investigating 2,146 samples, we initially detected SARS-CoV-2 antibodies in 94.4%
Neutralizing Autoantibodies to Type I Interferons in COVID-19 Convalescent Donor Plasma.
Sara E Vazquez et al.
Journal of clinical immunology, 41(6), 1169-1171 (2021-05-20)
Kanika Vanshylla et al.
Cell host & microbe, 30(1), 69-82 (2022-01-02)
A fraction of COVID-19 convalescent individuals mount a potent antibody response to SARS-CoV-2 with cross-reactivity to SARS-CoV-1. To uncover their humoral response in detail, we performed single B cell analysis from 10 SARS-CoV-2 elite neutralizers. We isolated and analyzed 126
Monique G P van der Wijst et al.
Science translational medicine, 13(612), eabh2624-eabh2624 (2021-08-26)
Neutralizing autoantibodies against type I interferons (IFNs) have been found in some patients with critical coronavirus disease 2019 (COVID-19), the disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, the prevalence of these antibodies, their longitudinal dynamics across

Cikkek

Purify monoclonal or polyclonal IgG from serum, cell culture supernatant or ascitic fluid using the HiTrap Protein G HP from Cytiva, an affinity-exclusion chromatography product containing Sepharose-immobilized Protein G.

This page describes immunoprecipitation (immunoaffinity or pull-down techniques).

This page describes efficient column packing and preparation for affinity chromatography of antibodies.

This page shows how to convert between flow velocity and volumetric flow rate in affinity chromatography of antibodies.

Összes mutatása

Protocols

This page provides information about different pull-down assays for the further isolation of multiprotein complexes to identify their components with products from Cytiva.

Ez az oldal a multiprotein-komplexek további izolálására szolgáló különböző pull-down próbákról nyújt információt, amelyek célja a Cytiva termékeivel történő komponensek azonosítása.

This page shows how to separate IgG antibodies by affinity chromatography using Protein G Sepharose 4 Fast Flow from Cytiva.

This page shows how to prepare samples for purification with affinity chromatography.

Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.

Lépjen kapcsolatba a szaktanácsadással