Ugrás a tartalomra
Merck
Összes fotó(1)

Fontos dokumentumok

I-026

Supelco

Interference Mix 4 (For Qualitative Use Only)

5-100 μg/mL each component in methanol, Cerilliant®

Szinonimák:

Qualitative Interference Mixture

Bejelentkezésa Szervezeti és Szerződéses árazás megtekintéséhez


About This Item

UNSPSC kód:
41116107
NACRES:
NA.24

grade

analytical standard

Forma

liquid

összetétel

Alprazolam, 100 μg/mL
Cimetidine, 100 μg/mL
Citalopram hydrobromide, 100 μg/mL (as free base)
Clonazepam, 100 μg/mL
Clopidogrel bisulfate, 100 μg/mL (as free base)
Dextromethorphan, 50 μg/mL
Fluconazole, 100 μg/mL
Hydrochlorothiazide, 100 μg/mL
Lamotrigine, 100 μg/mL
Methylphenidate hydrochloride, 100 μg/mL (as free base)
Omeprazole, 100 μg/mL
L-Thyroxine, 5 μg/mL

kiszerelés

ampule of 1 mL

gyártó/kereskedő neve

Cerilliant®

drug control

psicótropo (Spain); Decreto Lei 15/93: Tabela IV/IIB (Portugal)

koncentráció

5-100 μg/mL each component in methanol

technika/technikák

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

alkalmazás(ok)

forensics and toxicology

Formátum

single component solution

tárolási hőmérséklet

−20°C

Looking for similar products? Látogasson el ide Útmutató a termékösszehasonlításhoz

Általános leírás

A multi-component solution standard of routinely monitored over-the-counter (OTC) and prescription drugs alprazolam; cimetidine; citalopram HBr; clonazepam; clopidogrel bisulfate; dextromethorphan; fluconazole; hydrochlorothiazide; lamotrigine; L-thyroxine; methylphenidate HCl; and omeprazole. This standard is for qualitative use only in the evaluation of interferences between the mix components and target analytes of interest in a testing laboratory′s analytical methods.

Alkalmazás


  • VOCs Determination in Complex Mixtures: Metal oxide-based gas sensor arrays enhanced with machine learning, utilizing Interference Mix 4 for calibration and validation, revolutionize volatile organic compounds analysis in biotechnological applications (Singh et al., 2024).

  • Ammonia Sensing Technology: Development of a highly sensitive ammonia sensor using a PMMA/PANI microwire structure, where Interference Mix 4 serves to test interference resilience, pivotal for maintaining lab environment quality in pharma research (Cheng et al., 2024).

  • Anticoagulant Interference in Medical Testing: Simplified method for removing direct oral anticoagulant interference in mechanical coagulation test systems, employing Interference Mix 4 to validate the approach, essential for accurate clinical diagnostics in medical biotechnology (Exner et al., 2024).

Jogi információk

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany

Figyelmeztetés

Danger

Figyelmeztető mondatok

Veszélyességi osztályok

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

Célzott szervek

Eyes,Central nervous system

Tárolási osztály kódja

3 - Flammable liquids

WGK

WGK 2

Lobbanási pont (F)

49.5 °F - closed cup

Lobbanási pont (C)

9.7 °C - closed cup


Válasszon a legfrissebb verziók közül:

Analitikai tanúsítványok (COA)

Lot/Batch Number

Sajnos jelenleg COA nem áll rendelkezésre ehhez a termékhez online.

Ha segítségre van szüksége, lépjen velünk kapcsolatba Vevőszolgálat

Már rendelkezik ezzel a termékkel?

Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.

Dokumentumtár megtekintése

Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.

Lépjen kapcsolatba a szaktanácsadással