318191
Sodium phenoxide trihydrate
98%
Synonyma:
Sodium phenolate
Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen
About This Item
Doporučené produkty
Quality Level
assay
98%
form
solid
reaction suitability
core: sodium
mp
61-64 °C (lit.)
SMILES string
[Na+].[H]O[H].[H]O[H].[H]O[H].[O-]c1ccccc1
InChI
1S/C6H6O.Na.3H2O/c7-6-4-2-1-3-5-6;;;;/h1-5,7H;;3*1H2/q;+1;;;/p-1
InChI key
QAJGUMORHHJFNJ-UHFFFAOYSA-M
Application
<ul>
<li><strong>High-throughput quantification of ammonium content in Arabidopsis</strong>: Research utilizing sodium phenoxide trihydrate for detecting ammonium content in Arabidopsis thaliana leaves (Vega-Mas et al., 2015).</li>
<li><strong>Catalytic hydrolytic cleavage and oxy-cleavage of lignin linkages</strong>: Study on the effectiveness of sodium phenoxide trihydrate in the catalytic cleavage of lignin linkages (Xia et al., 2014).</li>
<li><strong>Ultrasonic-assisted technique as a novel method for removal of naphthenic acid from model oil using piperidinium-based ionic liquids</strong>: Investigation on the use of sodium phenoxide trihydrate in the synthesis of ionic liquids for removing naphthenic acid (Khaidzir et al., 2021).</li>
</ul>
<li><strong>High-throughput quantification of ammonium content in Arabidopsis</strong>: Research utilizing sodium phenoxide trihydrate for detecting ammonium content in Arabidopsis thaliana leaves (Vega-Mas et al., 2015).</li>
<li><strong>Catalytic hydrolytic cleavage and oxy-cleavage of lignin linkages</strong>: Study on the effectiveness of sodium phenoxide trihydrate in the catalytic cleavage of lignin linkages (Xia et al., 2014).</li>
<li><strong>Ultrasonic-assisted technique as a novel method for removal of naphthenic acid from model oil using piperidinium-based ionic liquids</strong>: Investigation on the use of sodium phenoxide trihydrate in the synthesis of ionic liquids for removing naphthenic acid (Khaidzir et al., 2021).</li>
</ul>
signalword
Danger
hcodes
Hazard Classifications
Eye Dam. 1 - Skin Corr. 1B
Storage Class
8A - Combustible corrosive hazardous materials
wgk_germany
WGK 2
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges