Passa al contenuto
Merck
  • Selective extraction of antimycotic drugs from sludge samples using matrix solid-phase dispersion followed by on-line clean-up.

Selective extraction of antimycotic drugs from sludge samples using matrix solid-phase dispersion followed by on-line clean-up.

Analytical and bioanalytical chemistry (2014-09-28)
Jorge Casado, Gabriela Castro, Isaac Rodríguez, María Ramil, Rafael Cela
ABSTRACT

An effective and selective, modular sample preparation method for the extraction of eight antimycotic drugs, belonging to three different chemical classes, from digested sludge samples is proposed. To this end, matrix solid-phase dispersion (MSPD) was on-line connected with a cationic exchanger solid-phase extraction (SPE) cartridge. Analytes were extracted from the MSPD syringe, which contained the freeze-dried sludge sample dispersed with C18 plus a clean-up layer of primary and secondary amine (PSA) sorbent, with 10 mL of methanol. This extract flowed also through the SPE cartridge, where target compounds remained trapped while neutral interferences are released. After discarding the MSPD syringe, analytes were recovered with 10 mL of methanol (0.5% in NH3) before LC-MS/MS determination using a hybrid quadrupole time-of-flight (QTOF) mass spectrometer furnished with an electrospray ionization (ESI) source. In comparison with previously published sample preparation methodologies, the developed approach greatly simplifies sample handling and reduces attenuation of ESI ionization for sample extracts when compared to standard solutions. The obtained absolute recoveries ranged between 70 and 118%, and the limits of quantification (LOQs) of the method varied between 5 and 8 ng g(-1). Four antimycotic drugs were ubiquitous in urban sludge samples, with maximum average concentrations (above 400 ng g(-1)) corresponding to clotrimazole (CTZ). The screening capabilities of the LC-QTOF-MS system demonstrated that the developed modular extraction and purification methodology might be useful for the selective extraction of other basic drugs (e.g., sertraline, amitryptiline, and amiodarone) from sludge.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Metanolo, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanolo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ammonio acetato, ACS reagent, ≥97%
Sigma-Aldrich
Ammoniaca, 7 N in methanol
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Ammonio acetato, ≥99.99% trace metals basis
Sigma-Aldrich
Metanolo, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Metanolo, anhydrous, 99.8%
Sigma-Aldrich
Metanolo, Laboratory Reagent, ≥99.6%
Supelco
Ammonio acetato, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Metanolo, Absolute - Acetone free
Sigma-Aldrich
Ammonio acetato, for molecular biology, ≥98%
Sigma-Aldrich
Metanolo, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Metanolo, BioReagent, ≥99.93%
Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Sigma-Aldrich
Ammoniaca, 0.4 M in dioxane
Sigma-Aldrich
Ammoniaca, 2.0 M in ethanol
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Ammonia, anhydrous, ≥99.98%
USP
Metanolo, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Ammoniaca, 4 M in methanol
Sigma-Aldrich
Activated Charcoal Norit®, Norit® PK 1-3, from peat, steam activated, granular
Sigma-Aldrich
Ammoniaca, 0.4 M in THF
Supelco
Metanolo, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ammonio acetato, 99.999% trace metals basis
Sigma-Aldrich
Ammonio acetato, reagent grade, ≥98%
Sigma-Aldrich
Ammoniaca, 2.0 M in methanol
Sigma-Aldrich
Activated Charcoal Norit®, Norit® GAC 1240W, from coal, for potable water processing, steam activated, granular