Direkt zum Inhalt
Merck
  • Development of a UHPLC-MS/MS method for the determination of plasma histamine in various mammalian species.

Development of a UHPLC-MS/MS method for the determination of plasma histamine in various mammalian species.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-09-30)
Jia Liu, Lei Wang, Wenjuan Hu, Xiaoyan Chen, Dafang Zhong
ZUSAMMENFASSUNG

Histamine is an important mediator of anaphylactic reactions. Although several methods have been developed to measure histamine levels, each has its limitations. In this study, we developed and validated a convenient bioanalytical method for the qualitative and quantitative determination of histamine in plasma samples from humans, beagle dogs, Sprague-Dawley rats, and imprinting control region mice. A simple plasma protein precipitation method using acetonitrile was selected, and hydrophilic interaction liquid chromatography coupled with mass spectrometry was used for sample separation and detection. Histamine was subjected to gradient elution with acetonitrile, ammonium acetate buffer, and formic acid. A mass spectrometer equipped with an electrospray ionization source was operated in the positive-ion multiple reaction monitoring mode for the detection of histamine and the internal standard. The [M+H](+) transitions were m/z 112→95 for histamine and m/z 116→99 for d4-histamine, which was used as the internal standard. The lower limit of quantification was 0.2μg/L and the calibration range was 0.2-500μg/L. The overall recovery ranged from 93.6% to 102.8%. The intra- and inter-run precision and accuracy were <15% for plasma samples from all four species. The method was validated by measuring the plasma histamine concentrations in five healthy human volunteers. In conclusion, we have developed and validated a novel bioanalytical method for the quantification of histamine levels in plasma samples from various mammalian species.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitril, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ameisensäure, reagent grade, ≥95%
Sigma-Aldrich
Ameisensäure, ACS reagent, ≥96%
Sigma-Aldrich
Ammoniumacetat, ACS reagent, ≥97%
Sigma-Aldrich
Ameisensäure, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Acetonitril, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitril, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
Ammoniumacetat, ≥99.99% trace metals basis
Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitril, anhydrous, 99.8%
Sigma-Aldrich
Ameisensäure, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Ameisensäure, ACS reagent, ≥88%
Sigma-Aldrich
Ammoniumacetat, for molecular biology, ≥98%
Sigma-Aldrich
Acetonitril, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Ammoniumacetat -Lösung, for molecular biology, 7.5 M
Sigma-Aldrich
Acetonitril, biotech. grade, ≥99.93%
Supelco
Ammoniumacetat, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Ammoniumacetat, 99.999% trace metals basis
Sigma-Aldrich
Pyrazol, 98%
Sigma-Aldrich
Ameisensäure, ≥95%, FCC, FG
Sigma-Aldrich
Acetonitril, ReagentPlus®, 99%
Sigma-Aldrich
Ammoniumacetat, reagent grade, ≥98%
Sigma-Aldrich
Acetonitril, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitril, suitable for DNA synthesis, ≥99.9% (GC)
Supelco
Acetonitril, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitril, ≥99.5% (GC)
Sigma-Aldrich
Ammoniumacetat -Lösung, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Ammoniumacetat, BioXtra, ≥98%
USP
Lösungsmittelrückstände Klasse 2 - Acetonitril, United States Pharmacopeia (USP) Reference Standard