Pular para o conteúdo
Merck
  • Direct determination of chlorophenols in landfill leachates by solid-phase micro-extraction-gas chromatography-mass spectrometry.

Direct determination of chlorophenols in landfill leachates by solid-phase micro-extraction-gas chromatography-mass spectrometry.

Journal of chromatography. A (2002-11-29)
A Ribeiro, M H Neves, M F Almeida, A Alves, L Santos
RESUMO

Landfill leachates represent a serious environmental concern with regard to trace priority pollutants introduced into the aquatic environment. From the analytical point of view, they constitute complex matrices because of their high organic matter content and competition with the trace analytes in the extraction procedure. Although the use of SPME to extract chlorophenols in leachates has already been described in several publications, the limited number of chlorophenols restricts this analysis field of application. This paper presents a new analytical methodology to determine 13 chlorophenols and phenol by SPME-GC-MS in landfill leachates. The overall analysis was performed in 90 min and the detection limits range from 0.005 microg/l (pentachlorophenol) to 2.5 microg/l (phenol). Reproducibility, expressed by the coefficient of variation of repeated extractions at different concentration levels of the analytes, was on average inferior to 10%. Recovery, evaluated by standard addition to leachates, was 86.2% on average. Pentachlorophenol, 2,3,4,5-tetrachlorophenol and 2,3,4,6-tetrachlorophenol were the sole analytes detected at nanogram level in the landfill leachates analysed.

MATERIAIS
Número do produto
Marca
Descrição do produto

Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
Conjunto de fibras para microextração em fase sólida (SPME) de polidimetilsiloxano (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Conjunto de fibras para microextração em fase sólida (SPME) de polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
Conjunto de fibras para microextração em fase sólida (SPME) de polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Conjunto de fibras para microextração em fase sólida (SPME) de poliacrilato (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
Conjunto de fibras para microextração em fase sólida (SPME) de poliacrilato (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
EPA 8040A Phenol Calibration Mix, 500 μg/mL each component in isopropanol, analytical standard
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPME StableFlex fiber assortment kit, for use with manual holder
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
2,3,4,6-Tetrachlorophenol, analytical standard
Supelco
Conjunto de fibras para microextração em fase sólida (SPME) de polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
2,3,5,6-Tetrachlorophenol, analytical standard
Supelco
SPME fiber assortment kit 4, for use with manual holder, size 24 ga