Direkt zum Inhalt
Merck
  • Optimization of an analytical methodology for the simultaneous determination of different classes of ultraviolet filters in cosmetics by pressurized liquid extraction-gas chromatography tandem mass spectrometry.

Optimization of an analytical methodology for the simultaneous determination of different classes of ultraviolet filters in cosmetics by pressurized liquid extraction-gas chromatography tandem mass spectrometry.

Journal of chromatography. A (2015-06-21)
Marlene Vila, J Pablo Lamas, Carmen Garcia-Jares, Thierry Dagnac, Maria Llompart
ZUSAMMENFASSUNG

A methodology based on pressurized liquid extraction (PLE) followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been developed for the simultaneous analysis of different classes of UV filters including methoxycinnamates, benzophenones, salicylates, p-aminobenzoic acid derivatives, and others in cosmetic products. The extractions were carried out in 1mL extraction cells and the amount of sample extracted was only 100mg. The experimental conditions, including the acetylation of the PLE extracts to improve GC performance, were optimized by means of experimental design tools. The two main factors affecting the PLE procedure such as solvent type and extraction temperature were assessed. The use of a matrix matched approach consisting of the addition of 10μL of diluted commercial cosmetic oil avoided matrix effects. Good linearity (R(2)>0.9970), quantitative recoveries (>80% for most of compounds, excluding three banned benzophenones) and satisfactory precision (RSD<10% in most cases) were achieved under the optimal conditions. The validated methodology was successfully applied to the analysis of different types of cosmetic formulations including sunscreens, hair products, nail polish, and lipsticks, amongst others.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Acetonitril, anhydrous, 99.8%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Pyridin, anhydrous, 99.8%
Sigma-Aldrich
Campher, 96%
Sigma-Aldrich
Ethylacetat, anhydrous, 99.8%
Sigma-Aldrich
Benzophenon, ReagentPlus®, 99%
Sigma-Aldrich
Essigsäureanhydrid, ReagentPlus®, ≥99%
Sigma-Aldrich
Essigsäureanhydrid, 99.5%
Sigma-Aldrich
Benzophenon, purified by sublimation, ≥99%
Sigma-Aldrich
Ethylacetat, ≥99%, FCC, FG
Sigma-Aldrich
Aceton, natural, ≥97%
Sigma-Aldrich
Ethylacetat
Sigma-Aldrich
Pyridin, ≥99%
Sigma-Aldrich
Aceton, ≥99%, meets FCC analytical specifications
Sigma-Aldrich
Acetonitril, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Ethylacetat, natural, ≥99%, FCC, FG
Sigma-Aldrich
Essigsäureanhydrid, ACS reagent, ≥98.0%
Sigma-Aldrich
2-Ethylhexyl-2-cyano-3,3-diphenylacrylat, 97%
Sigma-Aldrich
(±)-Campher, ≥95.5%
Sigma-Aldrich
Ethylacetat
Sigma-Aldrich
Methanol, NMR reference standard
Sigma-Aldrich
Ethylacetat, ReagentPlus®, ≥99.8%
Sigma-Aldrich
Essigsäureanhydrid, Arxada quality, ≥99.5% (GC)
Sigma-Aldrich
Methanol -Lösung, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
(±)-Campher, meets analytical specification of Ph. Eur., BP, racemic, ≥95% (GC)
Sigma-Aldrich
Aceton, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Acetonitril