Direkt zum Inhalt
Merck
  • Characterization of a highly sensitive and selective novel trapping reagent, stable isotope labeled glutathione ethyl ester, for the detection of reactive metabolites.

Characterization of a highly sensitive and selective novel trapping reagent, stable isotope labeled glutathione ethyl ester, for the detection of reactive metabolites.

Journal of pharmacological and toxicological methods (2015-09-01)
Toshikazu Yamaoka, Yoshiaki Kitamura
ZUSAMMENFASSUNG

Glutathione (GSH) trapping assays are widely used to predict the post-marketing risk for idiosyncratic drug reactions (IDRs) in the pharmaceutical industry. Although several GSH derivatives have been introduced as trapping reagents for reactive intermediates, more sensitive and selective reagents are desired to prevent the generation of erroneous results. In this study, stable isotope labeled GSH ethyl ester (GSHEE-d5) was designed and its detection capability was evaluated. GSHEE-d5 was synthesized and its detection potential was compared with stable isotope labeled GSH ([(13)C2,(15)N]GSH) as a reference trapping reagent. The trapping reagents were added to human liver microsomes as a 1:1 mixture with GSHEE or GSH, respectively, and incubated with seven IDR positive drugs and three IDR negative drugs. The adducts formed between the reagents and reactive metabolites were analyzed by unit resolution mass spectrometer (MS) using isotope pattern-dependent scan with neutral loss filtering. A single-step reaction of GSH and ethanol-d6 produced GSHEE-d5 with a yield of 85%. The GSHEE-d5 assay detected adducts with all seven IDR positive drugs, and no adducts were detected with the three IDR negative drugs. In contrast, the [(13)C2,(15)N]GSH assay failed to detect adducts with three of the IDR positive drugs. In the case of diclofenac, the GSHEE-d5 assay showed a 4-times greater signal intensity than the [(13)C2,(15)N]GSH assay. GSHEE-d5 enabled the detection of reactive metabolites with greater sensitivity and selectivity than [(13)C2,(15)N]GSH. These results demonstrate that GSHEE-d5 would be a useful trapping reagent for evaluating the risk of IDRs with unit resolution MS.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, for molecular biology
Sigma-Aldrich
Salzsäure, ACS reagent, 37%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Schwefelsäure, ACS reagent, 95.0-98.0%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Methanol-d4, ≥99.8 atom % D
Sigma-Aldrich
Salzsäure, ACS reagent, 37%
Sigma-Aldrich
Chlorwasserstoff -Lösung, 4.0 M in dioxane
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, meets USP testing specifications
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, for molecular biology
Sigma-Aldrich
DL-Dithiothreitol -Lösung, BioUltra, for molecular biology, ~1 M in H2O
Sigma-Aldrich
Diisopropylether, puriss. p.a., ≥98.5% (GC)
Sigma-Aldrich
Salzsäure -Lösung, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Magnesiumchlorid, anhydrous, ≥98%
Sigma-Aldrich
Methanol-d4, ≥99.8 atom % D
Sigma-Aldrich
Schwefelsäure, 99.999%
Sigma-Aldrich
Magnesiumchlorid -Lösung, for molecular biology, 1.00 M±0.01 M
Supelco
DL-Dithiothreitol -Lösung, 1 M in H2O
Sigma-Aldrich
Salzsäure, 37 wt. % in H2O, 99.999% trace metals basis
Sigma-Aldrich
Salzsäure, 36.5-38.0%, BioReagent, for molecular biology
Sigma-Aldrich
Chlorwasserstoff -Lösung, 2.0 M in diethyl ether
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Salzsäure, meets analytical specification of Ph. Eur., BP, NF, fuming, 36.5-38%
Sigma-Aldrich
L-Glutathion reduziert, suitable for cell culture, BioReagent, ≥98.0%, powder
Supelco
Salzsäure -Lösung, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Triethylamin, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, anhydrous, 99.8%