Direkt zum Inhalt
Merck

43809

Supelco

Perfluorhexansäure

analytical standard

Synonym(e):

Undecafluorhexansäure, Perfluorcapronsäure, Perfluorhexansäure

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
CF3(CF2)4COOH
CAS-Nummer:
Molekulargewicht:
314.05
Beilstein:
1805852
MDL-Nummer:
UNSPSC-Code:
41116107
NACRES:
NA.24
Preise und Verfügbarkeit sind derzeit nicht verfügbar.

Qualität

analytical standard

Qualitätsniveau

Agentur

suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA 8327
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for EPA OTM-45
suitable for ISO 21675 2019

Einhaltung gesetzlicher Vorschriften

suitable for FDA C-010.02

Assay

≥98.0% (GC)

Haltbarkeit

limited shelf life, expiry date on the label

Dichte

1.759 g/mL at 20 °C (lit.)

Format

neat

Lagertemp.

2-8°C

SMILES String

OC(=O)C(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)F

InChI

1S/C6HF11O2/c7-2(8,1(18)19)3(9,10)4(11,12)5(13,14)6(15,16)17/h(H,18,19)

InChIKey

PXUULQAPEKKVAH-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Perfluorohexanoic acid belonging to the class of perfluorinated carboxylic acids (PFCAs), with a 5-carbon perfluoroalkyl chain, was developed as an alternative to the environmental pollutant, perfluorooctanoic acid (PFOA).[1] The degradation of perfluorohexanoic acid is complex, due to the stability of the carbon-fluorine (C-F) bond.[2] It is most commonly used as a wetting agent, corrosion inhibitor, lubricant, and foam fire extinguishant.[3][4]

Anwendung

Perfluorohexanoic acid may be used as an analytical reference standard for the determination of the analyte in the following:        
  • biological samples using high-performance liquid chromatography (HPLC) with fluorescence detection[3]
  • dissolved/particulate phases of wastewater and sewage sludge using liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS)[5]        
  • whole blood samples using high-performance liquid chromatography- negative electrospray single quadrupole mass spectrometry (HPLC/ES-MS)[6]

Rechtliche Hinweise

ASTM is a registered trademark of American Society for Testing and Materials

Piktogramme

Corrosion

Signalwort

Danger

H-Sätze

Gefahreneinstufungen

Eye Dam. 1 - Skin Corr. 1B

Lagerklassenschlüssel

8A - Combustible corrosive hazardous materials

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Simultaneous determination of eighteen perfluorinated compounds in dissolved and particulate phases of wastewater, and in sewage sludge by liquid chromatography-tandem mass spectrometry
Arvaniti SO, et al.
Analytical Methods : Advancing Methods and Applications, 6(5), 1341-1349 (2014)
Comparison of the toxicokinetic behavior of perfluorohexanoic acid (PFHxA) and nonafluorobutane-1-sulfonic acid (PFBS) in cynomolgus monkeys and rats
Chengelis PC, et al.
Reproductive Toxicology, 27(3-4), 400-406 (2009)
Validation of a screening method based on liquid chromatography coupled to high-resolution mass spectrometry for analysis of perfluoroalkylated substances in biota
Berger U and Haukas M
Journal of Chromatography A, 1801(2), 210-217 (2005)
Determination of perfluorinated carboxylic acids in biological samples by high-performance liquid chromatography
Ohya T, et al.
Journal of Chromatography. B, Biomedical Sciences and Applications, 720(1-2), 1-7 (1998)
Development of a solid-phase extraction-HPLC/single quadrupole MS method for quantification of perfluorochemicals in whole blood
Karrman A, et al.
Analytical Chemistry, 77(3), 864-870 (2005)

Artikel

Liquid Chromatography–Mass Spectrometry (LC-MS) separation of 33 PFAS (Per- and poly-fluoroalkyl substances) using a superficially porous silica particles (SPP) based Ascentis® Express C18 column.

Discover an LC-MS/MS method for the analysis of 16 per- and polyfluoroalkyl compounds (PFAS) in milk using QuEChERS extraction technique following FDA C-010.02 guidelines.

Find more about the analysis of 16 PFAS in salmon via QuEChERS extraction and LC-MS/MS characterization following FDA Method C-010.02.

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.