You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.
S2GPU01RE
Millipore® Stericup® Schnellverschluss-Vakuumfiltrationssystem
pore size 0.22 μm, polyethersulfone membrane, funnel capacity 150 mL, pack of 12 ea
Synonym(e):
SCGPU01RE, Stericup Quick Release-GP steriles Vakuumfiltrationssystem
Größe auswählen
Größe auswählen
About This Item
Empfohlene Produkte
Materialien
polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing
Qualitätsniveau
Sterilität
sterile; irradiated
Produktlinie
Stericup®
Leistungsmerkmale
hydrophilic
Verpackung
pack of 12 ea
Parameter
45 °C max. temp.
Beschreibung
2.4 mL (hold-up volume)
Methode(n)
sterile filtration: suitable
Höhe
120 mm
Kapazität
150 mL
Durchmesser
12.5 cm
Filterdurchm.
73 mm
Filtrationsfläche
40 cm2
Trichterkapazität
150 mL
Matrix
Express PLUS™
Porengröße
0.22 μm pore size
Fitting
inlet funnel
outlet flask (Receiver)
Versandbedingung
ambient
Allgemeine Beschreibung
Die sterilen Stericup® und Steritop® Filtrationseinheiten verwenden zuverlässige Hochleistungsmembranen für eine optimale Sterilfiltration von Laborreagenzien, Puffern und Medien. Diese Geräte kombinieren überlegene Durchflussraten und Durchsatz mit geringer unspezifischer Bindung und einem stabilen Design ohne Spitzen.
Diese Stericup® Polyethersulfon(PES)-Membranfiltereinheit mit einer Porengröße von 0,22 μm kombiniert einen 150-ml-Flaschenverschluss mit einem 150-ml-Auffangkolben und Deckel für Verarbeitung und Lagerung.
Anwendung
- Gewebekulturmedien +/- Additive
- Puffer
- Biologische Lösungen
Leistungsmerkmale und Vorteile
- Der Schnellverschluss-Filtertrichter wird mit nur einer Vierteldrehung von der Sammelflasche getrennt,— was die Wahrscheinlichkeit eines Verschüttens verringert und die Handhabung auf dem Labortisch oder unter der Haube erleichtert.
- Die fett gedruckte Produktkennzeichnung auf dem Steritop® Filtertrichter zeigt deutlich die Membraneigenschaften einschließlich Zusammensetzung und Porengröße an, um eine schnelle, anwendungsgerechte Produktauswahl zu ermöglichen.
- Die Click-Dichtungskappe ist angeflanscht und modifiziert, um einen festen Halt unter nassen oder trockenen Bedingungen zu ermöglichen—und ein taktiler Anschlag bestätigt den sicheren Verschluss. Sorgen Sie sich weniger über die Möglichkeit eines Verschüttens oder einer Kontamination des sterilisierten Inhalts.
- Die matte, große Beschriftungsfläche auf der Auffangflasche und die hellere Deckelfarbe erleichtern die Lesbarkeit und reduzieren unleserliche Abstriche.
- Die Verschlusskappe liegt auf der Seite auf, um das Risiko einer Kontamination zu vermeiden.
- Die Auffangbehälter sind stapelbar, um Platz zu sparen.
Rechtliche Hinweise
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Kunden haben sich ebenfalls angesehen
Artikel
Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.
Verwandter Inhalt
This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.
-
Can Stericup® bottles be placed inside freezers for long-term storage of media?
1 answer-
Helpful?
-
-
What tubing can be used with Stericup® and Steritop® vacuum filters?
What tubing can be used with Stericup® and Steritop® vacuum filters?
1 answer-
Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004
Helpful?
-
-
Can we filter oil-type liquids with Stericup® filters?
Can we filter oil-type liquids with Stericup® filters?
1 answer-
Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
Helpful?
-
-
What leachables are detected during filtration processes using Stericup® filters?
1 answer-
We have not performed extractables/leachables studies for our Stericup® filters.
Helpful?
-
-
What Bacterial Endotoxins Test is used?
1 answer-
The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.
Helpful?
-
-
What is the expiration date of Stericup® and Steritop® filters?
1 answer-
Typically 3 years from sterilization.
Helpful?
-
-
What is the chemical compatibility of the various Stericup® and Steritop® filters?
What is the chemical compatibility of the various Stericup® and Steritop® filters?
1 answer-
Please refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
Helpful?
-
-
Are Stericup® and Steritop® filters GMP-certified?
1 answer-
No, Stericup® and Steritop® devices are not GMP-approved.
Helpful?
-
-
The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?
1 answer-
Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
Glass bottles, GL33:
• Wheaton media bottles (glass), 500 mL (Product Z364886)
• Wheaton media bottles (glass), 1 L (Product Z364894)
Glass bottles, GL45
• Corning® glass media storage bottle, 125 mL (Product CLS1399125)
• Corning® glass media storage bottle, 250 mL (Product CLS1399250)
• Corning® glass media storage bottle, 500 mL (Product CLS1399500)
• Corning® glass media storage bottle, 1 L (Product CLS13991L)
• Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
• Pyrex® round media storage bottle, 1 L (Product CLS13951L)
• KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
• KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
• KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
Plastic (pre-sterile) bottles, GL45:
• Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
• Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
• Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)Helpful?
-
-
What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?
1 answer-
All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
*Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.Helpful?
-
Active Filters
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.