Przejdź do zawartości
Merck
Wszystkie zdjęcia(1)

Kluczowe dokumenty

FCCH025111

Sigma-Aldrich

FlowCellect Oxidative Stress Characterization Kit

Oxidative stress has been found to play a key role in a number of pathological disorders.

Synonim(y):

FlowCellect

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
12161503
eCl@ss:
32161000

reaktywność gatunkowa (przewidywana na podstawie homologii)

all

producent / nazwa handlowa

FlowCellect

metody

flow cytometry: suitable

kompatybilność

for use with EasyCyte 8HT
for use with EasyCyte Mini
for use with EasyCyte Plus
for use with EasyCyte

metoda wykrywania

fluorometric

Warunki transportu

dry ice

Opis ogólny

Oxidative stress has been found to play a key role in a number of pathological disorders. To aid researchers studying this phenomenon Millipore has developed the FlowCellect Oxidative Stress Characterization Kit. This kit contains the chemical and immunological reagents necessary to detect carbonyl groups introduced onto proteins by reactive oxygen species (ROS). The test method involves derivatization of protein carbonyl groups with 2,4-dinitrophenylhydrazine (DNPH). This chemical reaction results in proteins being covalently coupled to DNP at their carbonyl sites. The DNP-derivatized proteins are then incubated with a FITC conjugated monoclonal antibody that specifically binds to the DNP moiety. Subsequent detection with a bench-top Guava EasyCyte Plus flow cytometer allows quantification of the extent of oxidative stress within cells. Although the assay and all of the kit components were optimized using a Guava instrument, any flow cytometer can be utilized provided it contains a blue laser (488 nm) light source.

Zastosowanie

Research Category
Neuroscience

Komponenty

Anti-DNP -FITC

Derivatization Control Solution

5X Assay Buffer

DNPH Solution

10X Wash Buffer

User Manual

Przechowywanie i stabilność

Upon arrival the FITC conjugated anti-DNP antibody should be transferred to a -20°C freezer. The remaining kit components (FCCH025111-1) should be stored at 2 - 8ºC.
All kit components are stable for up to six (6) months from date of receipt if stored and handled appropriately.

Informacje prawne

FlowCellect is a trademark of Luminex Corporation

Oświadczenie o zrzeczeniu się odpowiedzialności

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Ta strona może zawierać tekst przetłumaczony maszynowo.

Piktogramy

Corrosion

Hasło ostrzegawcze

Warning

Zwroty wskazujące środki ostrożności

Kod klasy składowania

8B - Non-combustible corrosive hazardous materials


Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Cristina Talarico et al.
Oncotarget, 7(13), 15868-15884 (2016-02-26)
Glioblastoma multiforme (GBM) is the most aggressive CNS tumor and is characterized by a very high frequency of clinical relapse after therapy and thus by a dismal prognosis, which strongly compromises patients survival. We have recently identified the small molecule

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej