コンテンツへスキップ
Merck
  • Evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry for species identification of Acinetobacter strains isolated from blood cultures.

Evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry for species identification of Acinetobacter strains isolated from blood cultures.

Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases (2013-10-16)
K Kishii, K Kikuchi, N Matsuda, A Yoshida, K Okuzumi, Y Uetera, H Yasuhara, K Moriya
要旨

The clinical relevance of Acinetobacter species, other than A. baumannii, as human pathogens has not been sufficiently assessed owing to the insufficiency of simple phenotypic clinical diagnostic laboratory tests. Infections caused by these organisms have different impacts on clinical outcome and require different treatment and management approaches. It is therefore important to correctly identify Acinetobacter species. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been introduced to identify a wide range of microorganisms in clinical laboratories, but only a few studies have examined its utility for identifying Acinetobacter species, particularly those of the non-Acinetobacter baumannii complex. We therefore evaluated MALDI-TOF MS for identification of Acinetobacter species by comparing it with sequence analysis of rpoB using 123 isolates of Acinetobacter species from blood. Of the isolates examined, we identified 106/123 (86.2%) to species, and 16/123 (13.0%) could only be identified as acinetobacters. The identity of one isolate could not be established. Of the 106 species identified, 89/106 (84.0%) were confirmed by rpoB sequence analysis, and 17/106 (16.0%) were discordant. These data indicate correct identification of 89/123 (72.4%) isolates. Surprisingly, all blood culture isolates were identified as 13 species of Acinetobacter, and the incidence of Acinetobacter pittii was unexpectedly high (42/123; 34.1%) and exceeded that of A. baumannii (22/123; 17.9%). Although the present identification rate using MALDI-TOF MS is not acceptable for species-level identification of Acinetobacter, further expansion of the database should remedy this situation.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
トリフルオロ酢酸, ReagentPlus®, 99%
Sigma-Aldrich
トリフルオロ酢酸, suitable for HPLC, ≥99.0%
Sigma-Aldrich
ギ酸, reagent grade, ≥95%
Sigma-Aldrich
ギ酸, ACS reagent, ≥96%
Sigma-Aldrich
トリフルオロ酢酸, puriss. p.a., suitable for HPLC, ≥99.0% (GC)
Sigma-Aldrich
ギ酸, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
アセトニトリル, ACS reagent, ≥99.5%
Sigma-Aldrich
アセトニトリル, ≥99.9% (GC)
Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
ギ酸, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
トリフルオロ酢酸, ≥99%, for protein sequencing
Sigma-Aldrich
ギ酸, ACS reagent, ≥88%
Sigma-Aldrich
アセトニトリル, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
アセトニトリル, biotech. grade, ≥99.93%
Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
ギ酸, ≥95%, FCC, FG
Sigma-Aldrich
アセトニトリル, ReagentPlus®, 99%
Sigma-Aldrich
アセトニトリル, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
アセトニトリル, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
ギ酸, JIS special grade, ≥98.0%
Sigma-Aldrich
アセトニトリル, ≥99.8%, suitable for HPLC
Supelco
アセトニトリル, Pharmaceutical Secondary Standard; Certified Reference Material
USP
アセトニトリル 溶液, United States Pharmacopeia (USP) Reference Standard
Supelco
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9% (GC)
Sigma-Aldrich
アセトニトリル, ≥99.8%, JIS 300
Sigma-Aldrich
ギ酸 溶液, BioUltra, 1.0 M in H2O
Sigma-Aldrich
アセトニトリル, JIS special grade, ≥99.5%
Sigma-Aldrich
トリフルオロ酢酸, SAJ special grade, ≥99.0%
Supelco
トリフルオロ酢酸, analytical standard