Yes. product 53304-U Ascentis® Express Peptide ES C18 HPLC columns are packed in a way making them suitable for these ultra high pressure instruments. In fact, product 53304-U Ascentis® Express Peptide ES C18 HPLC Column outperforms sub-2 μm micron columns on many applications since product 53304-U Ascentis® Express Peptide ES C18 HPLC Column provides the benefits of sub-2 μm particles but at much lower back pressure. These benefits include the capability of providing fast HPLC and higher resolution chromatography. The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell. A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.
53304-U
Ascentis® Express Peptide 160 Å ES-C18 (2.7 μm) HPLC Columns
L × I.D. 7.5 cm × 2.1 mm, HPLC Column
別名:
TM=["Ascentis"] Peptide Chromatography
サイズを選択してください
¥109,000
サイズを選択してください
About This Item
¥109,000
おすすめの製品
製品名
Ascentis® Express Peptide ES-C18, 2.7 μm HPLCカラム, 2.7 μm particle size, L × I.D. 7.5 cm × 2.1 mm
物質
stainless steel column
認証
suitable for USP L1
製品種目
Ascentis®
特徴
endcapped: no
メーカー/製品名
Ascentis®
包装
1 ea of
パラメーター
≤100 °C temp. range
600 bar max. pressure (9000 psi)
テクニック
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
L × 内径
7.5 cm × 2.1 mm
表面積
90 m2/g
不純物
<5 ppm metals
Matrix
Fused-Core particle platform
superficially porous particle
マトリックス活性基
C18 (octadecyl) phase
粒径
2.7 μm
ポアサイズ
160 Å
動作pH範囲
1-9
分離法
reversed phase
類似した製品をお探しですか? 訪問 製品比較ガイド
関連するカテゴリー
詳細
法的情報
ガードカートリッジ
必要ですが提供されていません
保管分類コード
11 - Combustible Solids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
最新バージョンのいずれかを選択してください:
試験成績書(COA)
資料
Choose Ascentis® Express Peptide ES-C18 U/HPLC Columns based on Fused-Core® technology for fast and efficient separation of high-molecular weight compounds, such as peptides and small proteins. With a 2.7 µm particle size and rigorous testing, these columns offer reliable results and high efficiency.
-
Can I use product 53304-U Ascentis® Express Peptide ES C18 HPLC Column on a UHPLC system?
1 回答-
役に立ちましたか?
-
-
Can I use product 53304-U Ascentis® Express Peptide ES C18 HPLC Column on any type of HPLC system?
1 回答-
Product 53304-U Ascentis® Express Peptide ES C18 HPLC Column HPLC columns is capable of use on standard HPLC systems as well as UHPLC systems. This column is packed in high pressure hardware capable of withstanding the pressures used in UHPLC systems.
役に立ちましたか?
-
-
Do I need special fittings and tubing to connect product 53304-U Ascentis® Express Peptide ES C18 HPLC ColumnExpress columns?
1 回答-
While operating pressures may not exceed the 400 bar (6,000 psi) capability of your traditional instruments, sustained pressures of about 200 bar (3,000 psi) will exceed the recommended pressure for conventional PEEK tubing and fittings at the column inlet. We recommend changing to stainless steel fittings in all high pressure locations and have designed special High Performance HPLC Fittings/Interconnects that will stay tight at pressures of 1,000 bar (15,000 psi) or greater, even when elevated column temperatures are employed.
役に立ちましたか?
-
-
How can I measure my instrument bandwidth (IBW) and determine what columns can be used with minimal efficiency loss created by too much internal instrument volume?
1 回答-
The Guide to Dispersion Measurement has simple instructions on how to measure IBW and can be found at sigma-aldrich.com/express.
役に立ちましたか?
-
-
Is there anything special I need to do to my HPLC system to use product 53304-U Ascentis® Express Peptide ES C18 HPLC Column?
1 回答-
Nothing special is required to use product 53304-U Ascentis® Express Peptide ES C18 HPLC Column. To obtain the full benefits of Ascentis® Express Column, one should minimize dispersion or instrument bandwidth in the HPLC system (tubing, detector flow cell) as well as confirm the detector response system is set at a fast level. For more information, request Guidelines for Optimizing Performance with Ascentis® Express HPLC Columns (T407102).
役に立ちましたか?
-
-
What flow rate should I use with product 53304-U Ascentis® Express Peptide ES C18 HPLC columns?
1 回答-
Based on the minimum in the van Deemter curves, higher flows than 5um particle columns are required in order to maximize product 53304-U Ascentis® Express Peptide ES C18 HPLC column efficiency. The suggested starting point for flow rate for Ascentis® Express columns: 1.6 mL/min for 4.6 mm ID; 0.8 mL/min for 3.0 mm ID; and 0.4mL/min for 2.1 mm ID.
役に立ちましたか?
-
-
What is the pressure rating for product 53304-U Ascentis® Express Peptide ES C18 HPLC Column?
1 回答-
This product 53304-U Ascentis® Express Peptide ES C18 HPLC Column is stable to operating pressures up to 600 bar (9000 psi)
役に立ちましたか?
-
-
What is the carbon load for product 53304-U Ascentis® Express Peptide ES C18 HPLC Column?
1 回答-
Carbon load which is commonly referred to as %Carbon is misleading and not meaningful for Ascentis Express. Since Fused-Core™ particle is unique in the sense that it has a solid core and porous shell, the %Carbon number can not be compared to traditional porous particles. The carbon coverage for product 53304-U Ascentis® Express Peptide ES C18 HPLC column is 2 micromoles/meter-squared.
役に立ちましたか?
-
-
What is the Department of Transportation shipping information for this product?
1 回答-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
役に立ちましたか?
-
-
Are guard columns available for product 53304-U Ascentis® Express Peptide ES C18 HPLC Column?
1 回答-
Yes, we have guard columns available for product 53304-U Ascentis® Express Peptide ES C18 HPLC Column. Product 53500-U is the Ascentis® Express Guard Holder and Product 53536-U Ascentis® Express Peptide ES C18 Guard Cartridge is a package of three guard cartridges, 2.7 μm particle size, L 5mm × I.D. 2.1 mm .
役に立ちましたか?
-
アクティブなフィルタ
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)