おすすめの製品
形状
liquid
品質水準
含まれません
preservative
メーカー/製品名
Calbiochem®
保管条件
OK to freeze
protect from light
色
clearvery light blue
輸送温度
ambient
保管温度
2-8°C
InChI
1S/C16H20N2/c1-9-5-13(6-10(2)15(9)17)14-7-11(3)16(18)12(4)8-14/h5-8H,17-18H2,1-4H3
InChI Key
UAIUNKRWKOVEES-UHFFFAOYSA-N
詳細
Peroxidase substrate that produces a blue soluble end product that can be read at 370 nm or 650 nm. Use of stop solution enhances sensitivity two- to four-fold and results in a yellow solution that can be read at 450 nm.
Soluble TMB substrate supplied as a single component system.
警告
Toxicity: Irritant (B)
物理的形状
Single component system containing 1.46 mM TMB, 2.21 mM H₂O₂ in a proprietary solvent, pH 3.1 ± 0.5.
再構成
Protect from exposure to direct sunlight. Discard if the solution turns blue or turbid. The reagent is stable at room temperature, but we recommend storage in the refrigerator for longer shelf life. Warm to assay temperature before use.
その他情報
Product tested for stability at 4°C and 18-26°C. Product performance is tested on the final product by ELISA.
Suggested Procedure for Use of TMB in HRP-based ELISAs:
1. Complete all required incubations with antibodies and HRP-labeled probes.
2. Wash plate wells at least 4 times with phosphate-buffered saline (PBS) or Tris-buffered saline (TBS), containing 0.1% Tween®-20 detergent.
3. After the final wash, shake and blot all residual buffer from the wells.
4. Add 100 μl TMB solution to each well and incubate for 5-30 min.
5. Options for measurements:
a. For kinetic assays, the reaction can be monitored as a function of time by reading absorbance at 650 nm at intermediate intervals.
b. For endpoint assays that preserve the blue chromogen, the reaction should be stopped by addition of 100 µl of 0.1% sodium fluoride (NaF) and the absorbance read at 650 nm.
c. If increased sensitivity is desired for endpoint assays, the reaction should be stopped by addition of 100 μl of either 500 mM H2SO4 or 250 mM HCl and the absorbance read at 450 nm WITHIN 5 MIN. Addition of acid converts the blue radical to the yellow diimine, which absorbs at 450 nm.
NOTE: Optimal incubation times may vary depending on the amount of HRP present. If color develops too quickly, zero-order kinetics will not prevail. Dilution of the probe, antibody, or HRP-labeled reagent may be required. Variations in time, reagent volumes, and temperature may also require further standardization by the user.
Suggested Procedure for Use of TMB in HRP-based ELISAs:
1. Complete all required incubations with antibodies and HRP-labeled probes.
2. Wash plate wells at least 4 times with phosphate-buffered saline (PBS) or Tris-buffered saline (TBS), containing 0.1% Tween®-20 detergent.
3. After the final wash, shake and blot all residual buffer from the wells.
4. Add 100 μl TMB solution to each well and incubate for 5-30 min.
5. Options for measurements:
a. For kinetic assays, the reaction can be monitored as a function of time by reading absorbance at 650 nm at intermediate intervals.
b. For endpoint assays that preserve the blue chromogen, the reaction should be stopped by addition of 100 µl of 0.1% sodium fluoride (NaF) and the absorbance read at 650 nm.
c. If increased sensitivity is desired for endpoint assays, the reaction should be stopped by addition of 100 μl of either 500 mM H2SO4 or 250 mM HCl and the absorbance read at 450 nm WITHIN 5 MIN. Addition of acid converts the blue radical to the yellow diimine, which absorbs at 450 nm.
NOTE: Optimal incubation times may vary depending on the amount of HRP present. If color develops too quickly, zero-order kinetics will not prevail. Dilution of the probe, antibody, or HRP-labeled reagent may be required. Variations in time, reagent volumes, and temperature may also require further standardization by the user.
法的情報
CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany
TWEEN is a registered trademark of Croda International PLC
シグナルワード
Warning
危険有害性情報
危険有害性の分類
Acute Tox. 4 Oral - Aquatic Chronic 4 - Carc. 2
保管分類コード
11 - Combustible Solids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
613544-100ML:
613544-ML:
US2613544-100ML:
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
この製品を見ている人はこちらもチェック
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)