Passa al contenuto
Merck
  • Solid-phase micro-extraction procedure for the determination of 1,3-dichloro-2-propanol in water by on-fibre derivatisation with bis(trimethylsilyl)trifluoroacetamide.

Solid-phase micro-extraction procedure for the determination of 1,3-dichloro-2-propanol in water by on-fibre derivatisation with bis(trimethylsilyl)trifluoroacetamide.

Analytical and bioanalytical chemistry (2009-04-11)
Antonia María Carro, Paula González, Noelia Fajar, Rosa Antonia Lorenzo, Rafael Cela
ABSTRACT

The headspace solid-phase micro-extraction technique with on-fibre derivatisation followed by gas chromatography-tandem mass spectrometry has been evaluated for the analysis of 1,3-dichloro-2-propanol in water. An asymmetric factorial design has been performed to study the influence of five experimental factors: extraction time and temperature, derivatisation time and temperature and pH. The best extraction performance is achieved in the headspace mode, with 5 mL stirred water samples (pH 4) containing 1.3 g of NaCl, equilibrated for 30 min at 25 degrees C, using divinylbenzene-carboxen-polydimethylsiloxane as the fibre coating. On-fibre derivatisation has been used for the first time with 50 microL of bis(trimethylsilyl)trifluoroacetamide at 25 degrees C during 15 min, leading to effective yields. The proposed method provides high sensitivity, good linearity and repeatability (relative standard deviation of 5.1% for 10 ng mL(-1) and n = 5). The limits of detection and quantification were 0.4 and 1.4 ng mL(-1), respectively. Analytical recoveries obtained for different water samples were approx. 100%.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
ORBO 90 Carboxen® 564 (20/45), 160/80 mg, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Sigma-Aldrich
(±)-3-Chloro-1,2-propanediol, 98%
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
Adsorbente Carboxen®, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
ORBO 78 HBr on Carboxen® 564 specially cleaned (20/45), 400/200 mg, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea
Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Sigma-Aldrich
1,3-Dichloro-2-propanol, 97%
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Colonna capillare per GC Carboxen®-1006 PLOT, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Gruppo fibre SPME poliacrilato (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Gruppo fibre SPME poliacrilato (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder