53972-U

Supelco

Ascentis® Express 90 Å HILIC (2.7 μm) HPLC Columns

L × I.D. 15 cm × 3 mm, HPLC Column

Sinonimo/i:

Core-shell (SPP) Fused Core Si HPLC column

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

1 EA
893,00 €

893,00 €


Per informazioni sulla disponibilità, contatta il Servizio Clienti.


Scegli un formato

Cambia visualizzazione
1 EA
893,00 €

About This Item

Codice UNSPSC:
41115700
eCl@ss:
32110501
NACRES:
SB.52

893,00 €


Per informazioni sulla disponibilità, contatta il Servizio Clienti.

Nome del prodotto

Ascentis® Express HILIC HPLC Column, 2.7 μm particle size, L × I.D. 15 cm × 3 mm

Materiali

stainless steel column

agenzia

suitable for USP L3

Nome Commerciale

Ascentis®

Caratteristiche

endcapped: no

Produttore/marchio commerciale

Ascentis®

Confezionamento

1 ea of

Parametri

≤100 °C temp. range
600 bar max. pressure (9000 psi)

tecniche

HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable

Lungh. × D.I.

15 cm × 3 mm

Area superficiale

135 m2/g

Impurezze

<5 ppm metals

Matrice

Fused-Core particle platform
superficially porous particle

Gruppo funzionale matrice

silica phase

Dimensione particelle

2.7 μm

Dimensione pori

90 Å

pH di lavoro

1-8

applicazioni

food and beverages

Tecnica di separazione

hydrophilic interaction (HILIC)
normal phase

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

Ascentis Express HPLC columns, through the use of Fused-Core® particle technology, can provide you with both the high speed and high efficiencies of sub-2 μm particles while maintaining lower backpressures. The combination of high efficiency and low backpressure benefits UPLC® (or other ultra high pressure system) users, as well as conventional HPLC users.
Visit the Ascentis Express home page for more information on this new column technology.

Note legali

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Fused-Core is a registered trademark of Advanced Materials Technology, Inc.
UPLC is a registered trademark of Waters

Precolonna

Prodotti correlati

N° Catalogo
Descrizione
Determinazione del prezzo

Richiesto ma non fornito

N° Catalogo
Descrizione
Determinazione del prezzo

Codice della classe di stoccaggio

11 - Combustible Solids

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Travis J Gates et al.
Biotechnology progress, 36(1), e2923-e2923 (2019-10-07)
Ultrafiltration and diafiltration (UF/DF) processes by tangential flow filtration (TFF) are frequently used for removal of solvents and small molecule impurities and for buffer exchange for biopharmaceutical products. Antibody-drug conjugates (ADCs) as an important class of biological therapeutics, carry unique
Paweł Kubica et al.
Journal of pharmaceutical and biomedical analysis, 127, 184-192 (2016-01-20)
Hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass spectrometry (MS/MS) was used to separate artificial and natural sweeteners approved for use in European Union (EU). Among three tested HILIC columns (BlueOrchid PAL-HILIC, Ascentis Express Si and Acclaim™ Trinity™ P2)
Imran Ali et al.
Biomedical chromatography : BMC, 26(8), 1001-1008 (2012-01-13)
Superficially porous silica particles columns (SPSPCs) are manufactured by different companies. The most common have the brand names Halo, Ascentis Express and Kinetex. These columns provide super fast, sharp peaks and moderate sample loading and back pressure. These are available
Tiziana Bertolini et al.
Journal of chromatography. A, 1365, 131-139 (2014-09-23)
A simple, sensitive and fast hydrophilic interaction liquid chromatography (HILIC) method using ultraviolet diode-array detector (UV-DAD)/electrospray ionization tandem mass spectrometry was developed for the automated high performance liquid chromatography (HPLC) determination of sodium risedronate (SR) and its degradation products in
Alexandre Grand-Guillaume Perrenoud et al.
Journal of chromatography. A, 1360, 275-287 (2014-08-19)
Superficially porous particles (SPP), or core shell particles, which consist of a non-porous silica core surrounded by a thin shell of porous silica, have gained popularity as a solid support for chromatography over the last decade. In the present study

Articoli

For separation of polar compounds including polar neutrals, polar acids, and polar and non-polar basic amines use our Ascentis® Express HILIC column.

Protocolli

We offer the tools for the analysis of the metabolites; including certified reference standards, enzymes, substrates, and chromatographic products.

Domande

1–10 di 17 domande  
  1. Why is it recommended to run isocratically for HILIC methods?

    1 risposta
    1. When running in HILIC mode, both isocratic and gradient practices result in instability. If you keep the re-equilibration times constant, gradient should not be a problem, but changing this parameter can have a significant impact. It is not so much that it is bad as it is different than we are used to in reversed phase. Usually, we assume that once equilibrated (5, 10, 15 min, etc.), we can leave the system for any time period and come back to the same results. This does not appear to be the case in our studies of HILIC. Knowing that the re-equilibration time has an impact, you should get in the habit of making several injections with known re-equilibration times prior to making any development decisions. To get around this, isocratic runs are recommended. Attached are two posters; the first was presented at HPLC 2013 (Amsterdam) and the second was presented at Balaton Symposium on High Performance Separation Methods 2013 (Hungary). Both show 'reproducibility' at any set re-equilibration time is good but both show that if you change the re-equilibration time; then retention, peak shape and selectivity can change especially where ionic interactions are prevalent.

      Utile?

  2. Do I need special fittings and tubing to connect Ascentis® Express HPLC Columns?

    1 risposta
    1. While operating pressures may not exceed the 400 bar (6,000 psi) capability of your traditional instruments, sustained pressures of about 200 bar (3,000 psi) will exceed the recommended pressure for conventional PEEK tubing and fittings at the column inlet. We recommend changing to stainless steel fittings in all high pressure locations and have designed special High Performance HPLC Fittings/Interconnects that will stay tight at pressures of 1,000 bar (15,000 psi) or greater, even when elevated column temperatures are employed.

      Utile?

  3. What is the Department of Transportation shipping information for this product?

    1 risposta
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Utile?

  4. In HILIC separations, what happens if the sample is an aqueous matrix? Does it always have a negative effect?

    1 risposta
    1. Yes, it would be highly preferential (especially in this case where you want partitioning to dominate) to inject in high organic. That said, you can 'get away' with it if the injection volume can be kept small - much like we can inject low volumes of stronger solvents in RP mode, if needed. What you will want to do to minimize impact is to get as much retention on the analytes of interest as you can, this helps give the sample solvent some time to dissipate and negate the effects.

      Utile?

  5. How does the flow rate influence the water layer on the column?

    1 risposta
    1. We are not aware of any systematic studies with respect to the impact of flow rate on HILIC separations. Our concern would be that as you move to higher flow rates, you might observe peak shape issues due to the slow kinetics of IEX and adsorption mechanisms. If the retention mechanisms for a given system are partition dominated, this should be of less concern. It will be a case by case cause and effect.

      Utile?

  6. Can I use Ascentis Express on any type of HPLC system?

    1 risposta
    1. Ascentis Express HPLC columns are capable of use on standard HPLC systems as well as UHPLC systems.  Columns are packed in high pressure hardware capable of withstanding the pressures used in UHPLC systems.

      Utile?

  7. How can I measure my instrument bandwidth (IBW) and determine what Ascentis® Express HPLC Columns can be used with minimal efficiency loss created by too much internal instrument volume?

    1 risposta
    1. The Guide to Dispersion Measurement has simple instructions on how to measure IBW and can be found at sigma-aldrich.com/express.

      Utile?

  8. Can Ascentis® Express HPLC Columns be used for LC-MS?

    1 risposta
    1. Express Fused-Core™ particles were designed with LC-MS in mind. Even extremely short column lengths exhibit sufficient plate counts to show high resolving power. The flat van Deemter plots permit resolution to be maintained at very high flow rates to maximize sample throughput. All Ascentis stationary phases have been evaluated for MS compatibility during their development, and the Express phases are no exception. You can expect extremely low column bleed and background while maintaining longest possible column lifetime. A bonus of Ascentis Express columns for high throughput UHPLC and LC-MS is that they are extremely rugged and highly resistant to plugging, a very common failure mode for competitor columns.

      Utile?

  9. Is there anything special I need to do to my HPLC system to use Ascentis Express?

    1 risposta
    1. Nothing special is required to use Ascentis Express HPLC columns. To obtain the full benefits of Ascentis Express, one should minimize dispersion or instrument bandwidth in the HPLC system (tubing, detector flow cell) as well as confirm the detector response system is set at a fast level. For more information, request Guidelines for Optimizing Systems for Ascentis Express Columns (T407102)

      Utile?

  10. When you recommend only changing one parameter at a time, does this also refer to the total ionic strength?

    1 risposta
    1. If you change organic, try to keep the overall buffer concentration (and all other parameters, for that matter) constant. There are times when you will want to change both and perhaps pH/temp/etc. simultaneously, but that drastically complicates the system and thus should be avoided, if possible.

      Utile?

1–10 di 17 domande  

Recensioni

Nessuna valutazione