Passa al contenuto
Merck
Tutte le immagini(2)

Documenti fondamentali

311413

Sigma-Aldrich

Acido perclorico

ACS reagent, 60%

Sinonimo/i:

PCA

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

100 ML
52,80 €
500 ML
105,00 €
1 L
253,00 €
4 X 100 ML
272,00 €

52,80 €


Per informazioni sulla disponibilità, contatta il Servizio Clienti.

Richiedi un ordine bulk

Scegli un formato

Cambia visualizzazione
100 ML
52,80 €
500 ML
105,00 €
1 L
253,00 €
4 X 100 ML
272,00 €

About This Item

Formula condensata:
HClO4
Numero CAS:
Peso molecolare:
100.46
Numero MDL:
Codice UNSPSC:
12352106
ID PubChem:
NACRES:
NA.21

52,80 €


Per informazioni sulla disponibilità, contatta il Servizio Clienti.

Richiedi un ordine bulk

Grado

ACS reagent

Livello qualitativo

Tensione di vapore

7 mmHg ( 25 °C)

Stato

liquid

Impiego in reazioni chimiche

reagent type: oxidant

Concentrazione

60%

Impurezze

≤0.001% N compounds
≤5 ppm Silicate and phosphate (as SIO2)

Residuo alla calcinazione

≤0.003%

Colore

APHA: ≤10

Densità

1.535 g/mL at 25 °C

Anioni in tracce

chloride (Cl-): ≤0.001%
sulfate (SO42-): ≤0.001%

Cationi in tracce

Fe: ≤1 ppm
heavy metals: ≤1 ppm (by ICP)

Stringa SMILE

OCl(=O)(=O)=O

InChI

1S/ClHO4/c2-1(3,4)5/h(H,2,3,4,5)
VLTRZXGMWDSKGL-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Applicazioni

  • How microstructures, oxide layers, and charge transfer reactions influence double layer capacitances. Part 1: impedance spectroscopy and cyclic voltammetry to estimate electrochemically active surface areas (ECSAs).: Perchloric acid was employed for electrode cleaning and preparation, essential in electrochemical studies for accurate measurements and analysis in physical chemistry (Schalenbach et al., 2024).
  • Determination of phosphorus in commercially available milk using ion chromatography with perchloric acid deproteinization.: The research highlights the use of perchloric acid for deproteinization in ion chromatography, demonstrating its application in food chemistry and quality control (Yoshikawa et al., 2024).
  • Assessment of essential and potentially toxic metals in raw cow milk from Mukaturi town, Oromia Regional State, Ethiopia.: Perchloric acid was utilized for the digestion of milk samples, facilitating the determination of metal content through analytical techniques in environmental chemistry (Tola et al., 2024).
  • Fabrication and Characterization of an Electrochemical Platform for Formaldehyde Oxidation, Based on Glassy Carbon Modified with Multi-Walled Carbon Nanotubes and Electrochemically Generated Palladium Nanoparticles.: This study used perchloric acid in the modification of electrodes, crucial for developing advanced electrochemical sensors and analytical methods (Leniart et al., 2024).

Altre note

ACS specifications same as product 244252, except for concentration

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Acute Tox. 4 Oral - Eye Dam. 1 - Met. Corr. 1 - Ox. Liq. 1 - Skin Corr. 1A - STOT RE 2

Organi bersaglio

Thyroid

Codice della classe di stoccaggio

5.1A - Strongly oxidizing hazardous materials

Classe di pericolosità dell'acqua (WGK)

WGK 1

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

He-Ping Zhao et al.
Environmental science & technology, 47(3), 1565-1572 (2013-01-10)
We evaluated a strategy for achieving complete reduction of perchlorate (ClO(4)(-)) in the presence of much higher concentrations of sulfate (SO(4)(2-)) and nitrate (NO(3)(-)) in a hydrogen-based membrane biofilm reactor (MBfR). Full ClO(4)(-) reduction was achieved by using a two-stage
Dipanwita Das et al.
Journal of the American Chemical Society, 135(10), 4018-4026 (2013-02-28)
Catalytic four-electron reduction of O2 by ferrocene (Fc) and 1,1'-dimethylferrocene (Me2Fc) occurs efficiently with a dinuclear copper(II) complex [Cu(II)2(XYLO)(OH)](2+) (1), where XYLO is a m-xylene-linked bis[(2-(2-pyridyl)ethyl)amine] dinucleating ligand with copper-bridging phenolate moiety], in the presence of perchloric acid (HClO4) in
Dipanwita Das et al.
Journal of the American Chemical Society, 135(7), 2825-2834 (2013-02-12)
Selective two-electron plus two-proton (2e(-)/2H(+)) reduction of O(2) to hydrogen peroxide by ferrocene (Fc) or 1,1'-dimethylferrocene (Me(2)Fc) in the presence of perchloric acid is catalyzed efficiently by a mononuclear copper(II) complex, [Cu(II)(tepa)](2+) (1; tepa = tris[2-(2-pyridyl)ethyl]amine) in acetone. The E(1/2)
Anna Weinberg et al.
Journal of abnormal psychology, 124(4), 878-889 (2015-07-28)
Depressive disorders are associated with significant economic and public health burdens as well as increased morbidity. Yet, perhaps due to the heterogeneous nature of the disease, prevention and intervention efforts are only moderately efficacious. A better understanding of core mechanisms
Kristiina Cajanus et al.
The journal of pain : official journal of the American Pain Society, 15(12), 1248-1256 (2014-09-23)
Most clinically used opioids are mu-opioid receptor agonists. Therefore, genetic variation of the OPRM1 gene that encodes the mu-opioid receptor is of great interest for understanding pain management. A polymorphism 118A>G (rs1799971) within the OPRM1 gene results in a missense

Domande

1–2 di 2 domande  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 risposta
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Utile?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 risposta
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Utile?

Recensioni

Nessuna valutazione

Filtri attivi

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.