55248-U
Supel™ QuE
Empty Centrifuge Tube with Lid, centrifuge tube volume 50 mL, pk of 50, suitable for EN 15662:2008 per BS
Szinonimák:
QuEChERS
About This Item
Javasolt termékek
Ügynökség
AOAC® 2007.01
suitable for BS EN 15662:2008
összetétel
empty tube (n/a)
kiszerelés
pk of 50
technika/technikák
QuEChERS: suitable
centrifuga cső térfogata
50 mL
alkalmazás(ok)
food and beverages
Looking for similar products? Látogasson el ide Útmutató a termékösszehasonlításhoz
Általános leírás
Using the QuEChERS method, food/agricultural samples are first extracted with an aqueous miscible solvent (e.g., acetonitrile) in the presence of high amounts of salts (e.g., sodium chloride and magnesium sulfate) and/or buffering agents (e.g. citrate) to induce liquid phase separation and stabilize acid and base labile pesticides, respectively. Upon shaking and centrifugation, an aliquot of the organic phase is subjected to further cleanup using SPE. Unlike traditional methods using SPE tubes, in dispersive SPE, cleanup is facilitated by mixing bulk amounts of SPE (e.g., Supelclean PSA, ENVI-Carb, and/or Discovery DSC-18) with the extract. After sample cleanup, the mixture is centrifuged and the resulting supernatant can either be analyzed directly or can be subjected to minor further treatment before analysis.
Supelco carries a line of vials and centrifuge tubes containing pre-determined amounts of salts and SPE sorbents to support the most common method configurations used today.
Alkalmazás
Jogi információk
Alkalmazás
Tárolási osztály kódja
13 - Non Combustible Solids
WGK
WGK 3
Lobbanási pont (F)
Not applicable
Lobbanási pont (C)
Not applicable
Válasszon a legfrissebb verziók közül:
Analitikai tanúsítványok (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumentumok section.
Ha segítségre van szüksége, lépjen velünk kapcsolatba Vevőszolgálat
Már rendelkezik ezzel a termékkel?
Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.
Az ügyfelek ezeket is megtekintették
Cikkek
Glyphosate and related compounds are measured in oatmeal and infant cereal using ion-exchange polymer-based particles for HPLC and SPE. Low level detection was obtained.
Use QuEChERS methods to analyze samples of milk for veterinary drugs.
Dual-layer cartridge achieves efficient SPE clean-up for challenging pesticide residue testing in turmeric and spices.
2-layer SPE cartridge efficiently reduces background for ginger contaminant analysis.
Protocols
HPLC-UV analysis of active compounds in marijuana-infused edibles for potency testing; complex matrix requires precise methods.
Paprika spice's PAH contamination risk due to environmental exposure highlights food safety concerns.
A paprikafűszer PAH-szennyezési kockázata a környezeti expozíció miatt rávilágít az élelmiszerbiztonsági aggályokra.
Rapid potency testing of marijuana-infused edibles using LC/MS on a biphenyl stationary phase detected eleven cannabinoids.
Chromatograms
suitable for GC, application for SPEapplication for HPLCsuitable for GC, application for SPEsuitable for GC, application for SPEMutasson többetTudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.
Lépjen kapcsolatba a szaktanácsadással