Přejít k obsahu
Merck
Všechny fotografie(1)

Key Documents

82119

Sigma-Aldrich

Propylbenzene

≥99.0% (GC)

Synonyma:

1-Phenylpropane

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Lineární vzorec:
C6H5CH2CH2CH3
Číslo CAS:
Molekulová hmotnost:
120.19
Beilstein/REAXYS Number:
1903006
EC Number:
MDL number:
UNSPSC Code:
12352100
PubChem Substance ID:
NACRES:
NA.22

vapor density

4.14 (vs air)

vapor pressure

2 mmHg ( 20 °C)

assay

≥99.0% (GC)

form

liquid

autoignition temp.

842 °F

expl. lim.

6 %

refractive index

n20/D 1.491 (lit.)
n20/D 1.491

bp

159 °C (lit.)

mp

−99 °C (lit.)

density

0.862 g/mL at 25 °C (lit.)

SMILES string

CCCc1ccccc1

InChI

1S/C9H12/c1-2-6-9-7-4-3-5-8-9/h3-5,7-8H,2,6H2,1H3

InChI key

ODLMAHJVESYWTB-UHFFFAOYSA-N

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

signalword

Danger

Hazard Classifications

Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 3 - STOT SE 3

target_organs

Respiratory system

Storage Class

3 - Flammable liquids

wgk_germany

WGK 2

flash_point_f

107.6 °F - closed cup

flash_point_c

42.0 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Zákazníci si také prohlíželi

S L Cruz et al.
British journal of pharmacology, 131(7), 1303-1308 (2000-11-23)
1. We have previously shown that toluene dose-dependently inhibits recombinant N-methyl-D-aspartate (NMDA) receptors at micromolar concentrations. This inhibition was rapid, almost complete and reversible. The NR1/2B combination was the most sensitive receptor subtype tested with an IC(50) value for toluene
R Andrew Shalliker et al.
Journal of chromatography. A, 1216(5), 787-793 (2008-12-20)
The effect of solvent viscosity mismatch on elution performance in reversed-phase HPLC was studied using moment analysis. Two conditions were tested: (1) the mobile phase viscosity was less than the injection plug viscosity, and (2) the mobile phase viscosity was
Sara Eriksson et al.
Biodegradation, 16(3), 253-263 (2005-05-04)
The metabolism of monoaromatic hydrocarbons by an iron-reducing bacterial enrichment culture originating from diesel-contaminated groundwater was examined using d7-propylbenzene as a model hydrocarbon. Sequence analysis of the 16S rDNA gene showed that the dominant part (10 of 10 clones) of
Matthew Giardina et al.
Analytical chemistry, 75(7), 1604-1614 (2003-04-23)
With increasing interest in the detection of disease-related volatile organic compounds (VOCs) found in human breath, breath analysis could prove to be a very useful diagnostic tool, especially for the early detection of lung cancer. Solid-phase microextraction (SPME) is a
J Schuberth
Journal of chromatographic science, 34(7), 314-319 (1996-07-01)
The full evaporation technique (FET), which is a variant of headspace analysis used to overcome matrix effects, was combined with capillary gas chromatography (GC) and ion-trap detection (ITD). The aim was to enable quantitative tests of volatile organic compounds (VOCs)

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.