Přejít k obsahu
Merck
Všechny fotografie(1)

Hlavní dokumenty

267724

Sigma-Aldrich

Zirconium

rod, diam. 6.35 mm, ≥99% trace metals basis

Synonyma:

Zirconium element

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Empirický vzorec (Hillův zápis):
Zr
Číslo CAS:
Molekulová hmotnost:
91.22
EC Number:
MDL number:
UNSPSC Code:
12141751
PubChem Substance ID:
NACRES:
NA.23

assay

≥99% trace metals basis

form

rod

resistivity

40 μΩ-cm, 20°C

diam.

6.35 mm

bp

4377 °C (lit.)

mp

1852 °C (lit.)

density

6.5 g/mL at 25 °C (lit.)

SMILES string

[Zr]

InChI

1S/Zr

InChI key

QCWXUUIWCKQGHC-UHFFFAOYSA-N

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

Quantity

100 g = 50 cm; 20 g = 10 cm

pictograms

Flame

signalword

Danger

hcodes

Hazard Classifications

Flam. Sol. 1

Storage Class

4.1B - Flammable solid hazardous materials

wgk_germany

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

Nevidíte správnou verzi?

Potřebujete-li konkrétní verzi, můžete vyhledat daný certifikát podle čísla dávky nebo čísla šarže.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Zákazníci si také prohlíželi

Slide 1 of 4

1 of 4

The enigma of the bilayered zirconia restoration.
Bernard E Keough et al.
Dentistry today, 32(5), 68-68 (2013-06-01)
O Tymofiyeva et al.
Dento maxillo facial radiology, 42(6), 20120271-20120271 (2013-04-24)
To investigate the potential influence of standard dental materials on dental MRI (dMRI) by estimating the magnetic susceptibility with the help of the MRI-based geometric distortion method and to classify the materials from the standpoint of dMRI. A series of
[New bipolar electrosurgical tools based on zirconium dioxide].
S V Belov et al.
Meditsinskaia tekhnika, (2)(2), 20-24 (2013-06-26)
New CAD/CAM materials and blocks for chairside procedures.
M Zimmermann et al.
International journal of computerized dentistry, 16(2), 173-181 (2013-08-13)
Surgical, biologic and implant-related factors affecting bone remodeling around implants.
Matteo Capelli
The European journal of esthetic dentistry : official journal of the European Academy of Esthetic Dentistry, 8(2), 279-313 (2013-05-29)

Sortimentní položky

Biomedical implants are essentially foreign substances within the human body that must survive many years’ exposure to demanding mechanical and physiological conditions. Despite these challenges, metal implants have been widely used to substitute for or rebuild hard tissues such as bones and teeth.

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.