1.02315
Calcein
metal indicator
Sinónimos:
Calcein indicator, 2,7-Bis[bis(carboxymethyl)aminomethyl]fluorescein
About This Item
Productos recomendados
product name
Calcein indicator, for metal determination
Quality Level
form
solid
loss
≤7.0% loss on drying, 110°C
bulk density
600 kg/m3
storage temp.
2-30°C
InChI
1S/C30H26N2O13/c33-21-7-23-19(5-15(21)9-31(11-25(35)36)12-26(37)38)30(18-4-2-1-3-17(18)29(43)45-30)20-6-16(22(34)8-24(20)44-23)10-32(13-27(39)40)14-28(41)42/h1-8,33-34H,9-14H2,(H,35,36)(H,37,38)(H,39,40)(H,41,42)
InChI key
DEGAKNSWVGKMLS-UHFFFAOYSA-N
Categorías relacionadas
Application
- The impacts of past, present and future ocean chemistry on predatory planktonic snails.: This study explores the influence of oceanic chemical changes on the biology and distribution of predatory planktonic snails, with calcein used as an indicator for tracking physiological responses in marine environments (Wall-Palmer et al., 2021).
- Statocalcein, a stable Calcein indicator for the EDTA titration of calcium.: This article introduces ′Statocalcein′, a novel and stable calcein derivative designed for enhanced precision in the EDTA titration methods used for calcium detection in various chemical analyses (Hoyle and Diehl, 1972).
- Evaluation of loop-mediated isothermal amplification assays for rapid detection of blaKPC producing Serratia spp. in clinical specimens: A prospective diagnostic accuracy study.: Although primarily focused on microbial identification, this study briefly mentions the use of calcein-based assays as a comparison to the loop-mediated isothermal amplification methods for rapid bacterial detection (Liu et al., 2021).
- Rapid and Specific Detection of All Known Nipah virus Strains′ Sequences With Reverse Transcription-Loop-Mediated Isothermal Amplification.: This paper references the use of calcein in a comparative study to highlight the efficacy of novel viral detection methods, showcasing its application in enhancing visual detection in assay systems (Ma et al., 2019).
Analysis Note
Loss on drying (110 °C): ≤ 7.0 %
Suitability as indicator (for metal titration): conforms
Storage Class
11 - Combustible Solids
wgk_germany
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico