About This Item

Empirische Formel (Hill-System):
C28H44O2
CAS-Nummer:
Molekulargewicht:
412.65
Beilstein:
4716773
MDL-Nummer:
UNSPSC-Code:
12352205
eCl@ss:
34058017
PubChem Substanz-ID:
NACRES:
NA.28

CHF 663.00


Check Cart for Availability

Bulk-Bestellung anfordern

Biologische Quelle

synthetic

Assay

≥95.0% (HPLC)

Form

crystalline powder

Farbe

white to off-white

mp (Schmelzpunkt)

88.0-95.0 °C

Lagertemp.

−70°C

SMILES String

[H][C@@]12CC[C@H]([C@H](C)\C=C\[C@H](C)C(C)(C)O)[C@@]1(C)CCC/C2=C\C=C3\C[C@@H](O)CCC3=C

InChI

1S/C28H44O2/c1-19-10-14-24(29)18-23(19)13-12-22-8-7-17-28(6)25(15-16-26(22)28)20(2)9-11-21(3)27(4,5)30/h9,11-13,20-21,24-26,29-30H,1,7-8,10,14-18H2,2-6H3/b11-9+,22-12+,23-13-/t20-,21+,24+,25-,26+,28-/m1/s1

InChIKey

KJKIIUAXZGLUND-ICCVIKJNSA-N

Biochem./physiol. Wirkung

Ergocalciferol (vitamin D2) is activated in vivo by hydroxylation to 25-hydroxyergocalciferol and 1α,25-dihydroxycalciferol. Activated Vitamin D2 molecules may be used in a wide range of studies to assess their effects on functions such as immune function and calcium homeostasis.

Verpackung

Amber polypropylene vial

Ähnliches Produkt

Produkt-Nr.
Beschreibung
Preisangaben

Piktogramme

Skull and crossbonesHealth hazard

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 2 Inhalation - Acute Tox. 3 Dermal - Acute Tox. 3 Oral - STOT RE 1 Oral

Lagerklassenschlüssel

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Stephen J Bruce et al.
Rapid communications in mass spectrometry : RCM, 27(1), 200-206 (2012-12-15)
The aim of the work was to develop and validate a method for the quantification of vitamin D metabolites in serum using ultra-high-pressure liquid chromatography coupled to mass spectrometry (LC/MS), and to validate a high-resolution mass spectrometry (LC/HRMS) approach against
Grant R Campbell et al.
PLoS pathogens, 8(11), e1003017-e1003017 (2012-11-21)
Toll-like receptors (TLR) are important in recognizing microbial pathogens and triggering host innate immune responses, including autophagy, and in the mediation of immune activation during human immunodeficiency virus type-1 (HIV) infection. We report here that TLR8 activation in human macrophages
Amin Salehpour et al.
Nutrition journal, 11, 78-78 (2012-09-25)
Vitamin D concentrations are linked to body composition indices, particularly body fat mass. Relationships between hypovitaminosis D and obesity, described by both BMI and waist circumference, have been mentioned. We have investigated the effect of a 12-week vitamin D3 supplementation
Kevin D Cashman et al.
The British journal of nutrition, 112(2), 193-202 (2014-05-02)
It has been suggested that vitamin D₂ is not very prevalent in the human food chain. However, data from a number of recent intervention studies suggest that the majority of subjects had measurable serum 25-hydroxyvitamin D₂ (25(OH)D₂) concentrations. Serum 25(OH)D₂
Paul Haggarty et al.
The British journal of nutrition, 109(5), 898-905 (2012-11-22)
The aims of the present study were to determine compliance with current advice on vitamin D and to assess the influence of season, dietary intake, supplement use and deprivation on vitamin D status in pregnant mothers and newborns in the

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.