Direkt zum Inhalt
Merck

11365

Supelco

Avicel® PH-101 Cellulose Resin

285 mesh

Synonym(e):

Cellulosepulver, mikrokristalline Cellulose, Baumwolllinters

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

1 KG
CHF 183.00

CHF 183.00


Voraussichtliches Versanddatum02. Juni 2025


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
1 KG
CHF 183.00

About This Item

CAS-Nummer:
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12000000
NACRES:
SB.52

CHF 183.00


Voraussichtliches Versanddatum02. Juni 2025


Bulk-Bestellung anfordern

Produktbezeichnung

Avicel® PH-101, ~50 μm particle size

Form

powder

Qualitätsniveau

Methode(n)

LPLC: suitable

Matrix

Cellulose

Aktive Matrixgruppe

polymer

Partikelgröße

~50 μm

Trenntechnik

size exclusion (SEC)

SMILES String

O1[C@H](C(C(C(C1CO)O)O)O)O[C@@H]2C(OC(C(C2O)O)O)CO

InChI

1S/C12H22O11/c13-1-3-5(15)6(16)9(19)12(22-3)23-10-4(2-14)21-11(20)8(18)7(10)17/h3-20H,1-2H2/t3?,4?,5?,6?,7?,8?,9?,10-,11?,12+/m1/s1

InChIKey

GUBGYTABKSRVRQ-WFVLMXAXSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Anwendung

  • Avicel® PH-101 wurde bei der Charakterisierung von mikrokristalliner Cellulose (MCC) mittels Pulver-Röntgenbeugung und Fourier-Transform-Infrarotspektroskopie als Referenzmaterial eingesetzt.[1]
  • Avicel® PH-101 wurde zum Bewerten des Kristallinitätsindex und zur Spektralanalyse von Cellulose mittels Röntgenbeugung und Festkörper-13C-NMR eingesetzt.[2]
  • Avicel® PH-101 wurde zur Aufbereitung von in Phosphorsäure gequellter Cellulose für einen Enzymassay mittels HPLC eingesetzt.[3]
Hochreines Cellulose-Pulver für die Verteilungschromatographie

Rechtliche Hinweise

Avicel is a registered trademark of FMC Corp.

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 1

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Gloves, type N95 (US)


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

The physicochemical characteristic of microcrystalline cellulose, derived from sawdust, agricultural waste products
Oyeniyi, Y. J., and O. A. Itiola.
International Journal of Pharmacy and Pharmaceutical Sciences, 4, 197-200 (2012)
Physicochemical, spectroscopic and thermal properties of microcrystalline cellulose derived from corn cobs.
Azubuike, Chukwuemeka P., and Augustine O. Okhamafe
International Journal of Recycling of Organic Waste in Agriculture, 1, 1-7 (2012)
Yasuya Fujita et al.
Applied and environmental microbiology, 70(2), 1207-1212 (2004-02-10)
A whole-cell biocatalyst with the ability to induce synergistic and sequential cellulose-degradation reaction was constructed through codisplay of three types of cellulolytic enzyme on the cell surface of the yeast Saccharomyces cerevisiae. When a cell surface display system based on
A staining technique for evaluating the pore structure variations of microcrystalline cellulose powders.
Yu, Xiaochun, and Rajai H. Atalla
Powder Technology, 98, 135-138 (1998)
Lara Hassan et al.
mBio, 10(4) (2019-07-04)
It is essential for microbes to acquire information about their environment. Fungi use soluble degradation products of plant cell wall components to understand the substrate composition they grow on. Individual perception pathways have been well described. However, the interconnections between

Questions

1–10 of 10 Questions  
  1. I would like to use Avicel in cell culture media. What is the best sterilization method? Can I autoclave the media with Avicel together with other components? Is there any concern about denaturation?

    1 answer
    1. Microcrystalline cellulose materials are generally considered to be stable and can withstand autoclaving, making them suitable for sterilization processes. However, it's important to consult specific product data sheets or manufacturer guidelines to confirm sterilization compatibility for your particular application, as formulations may vary. It is likely that standard autoclave settings, such as 121C for 15-30 minutes, would be effective.

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  4. What is the nominal surface charge density or number of charged groups in Avicel® PH-101?

    1 answer
    1. Avicel® PH-101, being microcrystalline cellulose, is generally considered to be neutral and does not have a significant charge at physiological pH levels (around 7.4). However, its surface can interact with ions depending on the pH of the environment. At very low pH (acidic conditions), the hydroxyl groups on the cellulose can become protonated, which might lead to a slight positive charge. Conversely, at very high pH (alkaline conditions), the cellulose may interact with hydroxide ions, but it still remains largely neutral.

      Helpful?

  5. What is the crystalline structure of Avicel? Is it Cellulose I or II?

    1 answer
    1. Avicel is a microcrystalline cellulose. The type of cellulose (I or II) is not designated. Please see the link below to review additional information regarding microcrystalline cellulose:
      https://www.sciencedirect.com/topics/medicine-and-dentistry/microcrystalline-cellulose

      Helpful?

  6. Is there a difference between Avicel PH-101 11363 and 11365 other than grams in the package? is one derived from the other? Is the particle size the same, and does it include the sodium carboxymethyl cellulose stabilizer?

    1 answer
    1. Product 11363 is tested according to pharmacopeia(Ph.) and European pharmacopoeia (Eur.) while product 11365 is a basic research grade item. Product 11363 is not tested for particle size. Neither product 11363 or product 11365 contain sodium carboxymethyl cellulose as a stabilizer. The major differences lie within the testing specifications. Please see the sample Certification of Analysis for more information:

      https://www.sigmaaldrich.com/certificates/sapfs/PROD/sap/certificate_pdfs/COFA/Q14/11365-BULKBCCJ9221.pdf
      https://www.sigmaaldrich.com/certificates/Graphics/COfAInfo/fluka/pdf/PDF740437.pdf

      Helpful?

  7. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  8. What is the loose bulk density of Avicel® PH-101?

    1 answer
    1. The loose bulk density is 0.26 to 0.31 grams/cubic centimeter.

      Helpful?

  9. What is the moisture content of Avicel® PH-101?

    1 answer
    1. The moisture content will vary in the range of 3 - 5%.

      Helpful?

  10. What is the nominal particle size of Avicel® PH-101 ?

    1 answer
    1. The mean particle size is approximately 50 microns.

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.