Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

D93503

Sigma-Aldrich

Dietilditiocarbamato de prata

ACS reagent, 99%

Sinônimo(s):

DETC, Ácido dietilditiocarbâmico

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula linear:
(C2H5)2NCSSAg
Número CAS:
Peso molecular:
256.14
Beilstein:
3718150
Número CE:
Número MDL:
Código UNSPSC:
12352100
ID de substância PubChem:
NACRES:
NA.21
Preço e disponibilidade não estão disponíveis no momento.

grau

ACS reagent

Nível de qualidade

Ensaio

99%

Formulário

powder

adequação da reação

core: silver
reagent type: catalyst

pf

172-175 °C (lit.)

grupo funcional

amine

temperatura de armazenamento

2-8°C

cadeia de caracteres SMILES

CCN(CC)C(=S)S[Ag]

InChI

1S/C5H11NS2.Ag/c1-3-6(4-2)5(7)8;/h3-4H2,1-2H3,(H,7,8);/q;+1/p-1

chave InChI

NSVHDIYWJVLAGH-UHFFFAOYSA-M

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

O dietilditiocarbamato de prata é usado para introduzir o ligante dietilditiocarbamato e para a determinação de arsênico.[1]

Aplicação

O dietilditiocarbamato de prata (AgDDC) pode ser usado no preparo de adutos de triorganofosfinas e difosfinas.[2]
Reagente do tipo “spin trap” usado conjugado com Fe2+ para detectar NO no cérebro, rim, fígado e outros tecidos. Foi relatada a medição direta simultânea de NO* e pO2. Como quelante de cobre, foi utilizado para quantificar cobre em materiais biológicos por RPE e é um inibidor de superóxido dismutase, ascorbato oxidase e outras enzimas.
Reagente para detecção de arsênio[3][4][5] e para a introdução do ligante dietilditiocarbamato.[6]
Também utilizada para determinação colorimétrica de pequenas quantidades de arsênio

Ações bioquímicas/fisiológicas

Inibe a indução da óxido nítrico sintase de macrófagos.

Código de classe de armazenamento

11 - Combustible Solids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable

Equipamento de proteção individual

dust mask type N95 (US), Eyeshields, Gloves


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

Inorganic Chemistry, 32, 3565-3565 (1993)
Hunjing Baohu, 23-23 (1991)
Synthesis and structural characterization of adducts of silver (I) diethyldithiocarbamate with P-donor ligands.
Di Nicola C, et al.
Inorgorganica Chimica Acta, 360(9), 2935-2943 (2007)
Chem. Abstr., 117, 219549d-219549d (1992)
Evaluation of electrochemical hydride generation for spectrophotometric determination of As (III) by silver diethyldithiocarbamat
Arbab-Zavar MH and Hashemi M
Talanta, 52, 1007-1014 (2000)

Questions

1–2 of 2 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica