Accéder au contenu
Merck
  • Simultaneous determination of sixteen amide fungicides in vegetables and fruits by dispersive solid phase extraction and liquid chromatography-tandem mass spectrometry.

Simultaneous determination of sixteen amide fungicides in vegetables and fruits by dispersive solid phase extraction and liquid chromatography-tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-03-24)
Yin-Liang Wu, Ruo-Xia Chen, Yong Zhu, Jian Zhao, Ting Yang
RÉSUMÉ

A modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) method using multi-walled carbon nanotubes (MWCNTs) as a reversed-dispersive solid phase extraction (r-dSPE) material combined with ultra-high liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) was developed for the simultaneous determination of 16 novel amide fungicides in vegetables and fruits. After extraction with acetonitrile, a dSPE cleanup procedure, which was developed after the optimization of the type and amount of MWCNTs, the pH value of the extract, the extraction time for MWCNTs, and the type of eluent with MWCNTs material, was conducted. The determination of the target compounds was conducted in less than 7.0 min while the specificity is ensured through the MRM acquisition mode. The linearity of the analytical response across the studied range of concentrations (0.25-500 μg/L) was excellent, obtaining correlation coefficients higher than 0.997. The samples were quantified with the matrix matched standard solutions. The average recoveries in cabbage, celery, strawberry, and grape at three spiked levels (0.01, 0.5, and 5.0mg/kg) were ranged from 72.4 to 98.5% with all RSDs lower than 10%. The limits of detection were below 0.003 mg/kg and the limits of quantification did not exceed 0.01 mg/kg in all matrices. The method demonstrated to be suitable for the simultaneous determination of 16 novel amide fungicides in vegetables and fruits.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acétonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Hydroxyde de sodium, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
Hydroxyde de sodium, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Acide formique, reagent grade, ≥95%
Sigma-Aldrich
Hydroxyde de sodium solution, 50% in H2O
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acide formique, ACS reagent, ≥96%
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acétonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Cyclohexane, ACS reagent, ≥99%
Sigma-Aldrich
Hydroxyde de sodium solution, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Cyclohexane, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Hydroxyde de sodium solution, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Hydroxyde de sodium, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
Hydroxyde de sodium, reagent grade, 97%, powder
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Hydroxyde de sodium, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
Acide formique, ACS reagent, ≥88%
Sigma-Aldrich
Hydroxyde de sodium, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
Hydroxyde de sodium solution, 5.0 M
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
Méthanol, Absolute - Acetone free
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
USP
Méthanol, United States Pharmacopeia (USP) Reference Standard