  • Optimisation and Characterisation of Anti-Fouling Ternary SAM Layers for Impedance-Based Aptasensors.

Optimisation and Characterisation of Anti-Fouling Ternary SAM Layers for Impedance-Based Aptasensors.

Sensors (Basel, Switzerland) (2015-10-02)
Anna Miodek, Edward M Regan, Nikhil Bhalla, Neal A E Hopkins, Sarah A Goodchild, Pedro Estrela
ZUSAMMENFASSUNG

An aptasensor with enhanced anti-fouling properties has been developed. As a case study, the aptasensor was designed with specificity for human thrombin. The sensing platform was developed on screen printed electrodes and is composed of a self-assembled monolayer made from a ternary mixture of 15-base thiolated DNA aptamers specific for human thrombin co-immobilised with 1,6-hexanedithiol (HDT) and further passivated with 1-mercapto-6-hexanol (MCH). HDT binds to the surface by two of its thiol groups forming alkyl chain bridges and this architecture protects from non-specific attachment of molecules to the electrode surface. Using Electrochemical Impedance Spectroscopy (EIS), the aptasensor is able to detect human thrombin as variations in charge transfer resistance (Rct) upon protein binding. After exposure to a high concentration of non-specific Bovine Serum Albumin (BSA) solution, no changes in the Rct value were observed, highlighting the bio-fouling resistance of the surface generated. In this paper, we present the optimisation and characterisation of the aptasensor based on the ternary self-assembled monolayer (SAM) layer. We show that anti-fouling properties depend on the type of gold surface used for biosensor construction, which was also confirmed by contact angle measurements. We further studied the ratio between aptamers and HDT, which can determine the specificity and selectivity of the sensing layer. We also report the influence of buffer pH and temperature used for incubation of electrodes with proteins on detection and anti-fouling properties. Finally, the stability of the aptasensor was studied by storage of modified electrodes for up to 28 days in different buffers and atmospheric conditions. Aptasensors based on ternary SAM layers are highly promising for clinical applications for detection of a range of proteins in real biological samples.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Kaliumphosphat, ACS reagent, ≥99.0%
Sigma-Aldrich
Trizma® Base, Primary Standard and Buffer, ≥99.9% (titration), crystalline
Sigma-Aldrich
Kaliumphosphat, ACS reagent, ≥98%
Sigma-Aldrich
Trizma® Base, BioPerformance Certified, meets EP, USP testing specifications, suitable for cell culture, ≥99.9% (titration)
Sigma-Aldrich
Kaliumhexacyanoferrat(III), ACS reagent, ≥99.0%
Sigma-Aldrich
Kaliumhexacyanoferrat(II) Trihydrat, ACS reagent, 98.5-102.0%
Sigma-Aldrich
Kaliumphosphat, powder, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99.0%
Sigma-Aldrich
Kaliumsulfat, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Tromethamin, meets USP testing specifications
Sigma-Aldrich
Kaliumhexacyanoferrat(II) Trihydrat, ReagentPlus®, ≥98.5%
Sigma-Aldrich
Sigma 7-9®, ≥99% (titration), crystalline
Sigma-Aldrich
Kaliumhexacyanoferrat(III), ReagentPlus®, ~99%
Sigma-Aldrich
Trizma® Base, BioUltra, for molecular biology, ≥99.8% (T)
Sigma-Aldrich
Kaliumsulfat, ACS reagent, ≥99.0%, powder
Sigma-Aldrich
Trizma® Base, ≥99.0% (T)
Sigma-Aldrich
Ethylendiamintetraessigsäure -Lösung, 0.02% in DPBS (0.5 mM), sterile-filtered, BioReagent, suitable for cell culture
Sigma-Aldrich
Kaliumsulfat, ACS reagent, ≥99.0%, powder or crystals
Sigma-Aldrich
Kaliumphosphat, for molecular biology, ≥98.0%
Sigma-Aldrich
Ethylendiamintetraessigsäure, anhydrous, crystalline, BioReagent, suitable for cell culture
Sigma-Aldrich
Ethylendiamintetraessigsäure, 99.995% trace metals basis
Sigma-Aldrich
Kaliumphosphat, anhydrous, for luminescence, for molecular biology, BioUltra, ≥99.0% (T)
Sigma-Aldrich
Trizma® Base, BioXtra, pH 10.5-12.0 (1 M in H2O), ≥99.9% (titration)
Sigma-Aldrich
6-Mercapto-1-hexanol, 97%
Sigma-Aldrich
Tris(hydroxymethyl)aminomethan, ACS reagent, ≥99.8%
Sigma-Aldrich
Ethylendiamintetraessigsäure, ACS reagent, 99.4-100.6%, powder
Sigma-Aldrich
Trizma® Base, ≥99.9% (titration), crystalline
Sigma-Aldrich
Kaliumphosphat -Lösung, 1.0 M
Sigma-Aldrich
Kaliumhexacyanoferrat(II) Trihydrat, ≥99.95% trace metals basis
Sigma-Aldrich
Kaliumhexacyanoferrat(II) Trihydrat, BioUltra, ≥99.5% (RT)
Sigma-Aldrich
Kaliumphosphat, ReagentPlus®