Direkt zum Inhalt
Merck

50053

Sigma-Aldrich

Glycidyltrimethylammoniumchlorid

technical, ≥90% (calc. based on dry substance, AT)

Synonym(e):

(2,3-Epoxypropyl)trimethylammoniumchlorid

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
C6H14ClNO
CAS-Nummer:
Molekulargewicht:
151.63
Beilstein:
3914931
MDL-Nummer:
UNSPSC-Code:
12352302
PubChem Substanz-ID:
NACRES:
NA.22
Preise und Verfügbarkeit sind derzeit nicht verfügbar.

Qualität

technical

Qualitätsniveau

Assay

≥90% (calc. based on dry substance, AT)

Verunreinigungen

2-4% chlorohydrin
20-25% water

Dichte

1.13 g/mL at 20 °C (lit.)

Lagertemp.

2-8°C

SMILES String

[Cl-].C[N+](C)(C)CC1CO1

InChI

1S/C6H14NO.ClH/c1-7(2,3)4-6-5-8-6;/h6H,4-5H2,1-3H3;1H/q+1;/p-1

InChIKey

PUVAFTRIIUSGLK-UHFFFAOYSA-M

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Glycidyltrimethylammoniumchlorid (GTMAC) ist ein kationisierendes Mittel, das häufig für die Modifizierung von Stärke verwendet wird.[1]

Anwendung

Glycidyltrimethylammoniumchlorid kann als derivatisierendes Mittel für die Synthese von N-(2-Hydroxypropyl)-3-Trimethylammoniumchitosanchlorid (HTCC), einem wasserlöslichen Chitosanderivat, durch eine Reaktion mit Chitosan verwendet werden. HTCC kann Nanokompositfilme bilden mit Silbernanopartikeln, die gute antimikrobielle Eigenschaften und optische Transparenz aufweisen.[2] Es können auch kationische Stärken durch Derivatisierung der Stärke mit GTMAC hergestellt werden.[3]

Vorsicht

Hydrolyse bei Lagerung (etwa 3,5 % pro Monat bei 20 °C)

Ähnliches Produkt

Produkt-Nr.
Beschreibung
Preisangaben

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Carc. 1B - Eye Dam. 1 - Muta. 2 - Repr. 1B - Skin Sens. 1 - STOT RE 2 - STOT SE 2

Zielorgane

Kidney

Lagerklassenschlüssel

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3

Flammpunkt (°F)

338.0 °F - closed cup

Flammpunkt (°C)

170 °C - closed cup

Persönliche Schutzausrüstung

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Zulassungslistungen

Zulassungslistungen werden hauptsächlich für chemische Produkte erstellt. Für nicht-chemische Produkte können hier nur begrenzte Angaben gemacht werden. Kein Eintrag bedeutet, dass keine der Komponenten gelistet ist. Es liegt in der Verantwortung des Benutzers, die sichere und legale Verwendung des Produkts zu gewährleisten.

EU REACH Annex XVII (Restriction List)

CAS No.

Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Jakarwan Yostawonkul et al.
Colloids and surfaces. B, Biointerfaces, 149, 301-311 (2016-10-26)
A nanostructure lipid carrier (NLC) composed of solid, and liquid lipid as a core has been developed as a delivery system for hydrophobic drug molecules. The aim of this research was to fabricate an oleoyl-quaternized-chitosan (CS)-coated NLC, where the mucoadhesive
Katariina Solin et al.
Small (Weinheim an der Bergstrasse, Germany), 16(50), e2004702-e2004702 (2020-11-21)
Soft cationic core/shell cellulose nanospheres can deform and interpenetrate allowing their self-assembly into densely packed colloidal nanogel layers. Taking advantage of their water-swelling capacity and molecular accessibility, the nanogels are proposed as a new and promising type of coating material
Joanna Grudzień et al.
Nanomaterials (Basel, Switzerland), 10(12) (2020-12-17)
The main focus of this work was to establish a correlation between surface topography and chemistry and surface colonization by lactic acid bacteria. For this reason, we chose gold substrates with different surface architectures (i.e., smooth and nanorough) that were
Nikolaos S Heliopoulos et al.
Pharmaceuticals (Basel, Switzerland), 13(10) (2020-10-11)
Oxidized multi-walled carbon nanotubes (oxCNTs) were functionalized by a simple non-covalent modification procedure using quaternized hyperbranched poly(ethyleneimine) derivatives (QPEIs), with various quaternization degrees. Structural characterization of these hybrids using a variety of techniques, revealed the successful and homogenous anchoring of
Xinlu Wang et al.
Frontiers in bioengineering and biotechnology, 7, 360-360 (2020-01-11)
Wound immersion in seawater with high salt, high sodium, and a high abundance of pathogenic bacteria, especially gram-negative bacteria, can cause serious infections and difficulties in wound repair. The present study aimed to prepare a composite hydrogel composed of hyaluronic

Questions

1–4 of 4 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. From this information “Caution hydrolysis on storage (approx. 3.5%/month at 20°C)”  If I keep in storage -18 °C it’s can keep product from approx.? Or reduce some loss?

    1 answer
    1. The recommended storage temperature for the product is 2-8 °C. The retest period for this item is approximately one year from the quality release date when stored in these conditions. There is no stability information available regarding storage at -18°C.

      Helpful?

  4. >90% Glycidyltrimethylammonium Chloride (#50053) has a water content between 20-25%. What would be the refractive index at a water content of 20 and 25%?

    1 answer
    1. The refractive index is not determined.

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.