跳轉至內容
Merck
全部照片(2)

重要文件

GE11-0034-94

HiTrap® MabSelect SuRe

Cytiva 11-0034-94, pack of 1 × 5 mL

同義詞:

HiTrap MabSelect SuRe, MabSelect SuRe Column

登入查看組織和合約定價


About This Item

分類程式碼代碼:
23151816
NACRES:
NA.56
暫時無法取得訂價和供貨情況

ligand

alkali-stabilized protein A-derived (E. coli)

包裝

pack of 1 × 5 mL

製造商/商標名

Cytiva 11-0034-94

儲存條件

(20% Ehtanol)
(20% Ethanol)

參數

<20 mL/min flow rate
42 psi

床尺寸

16 mm × 25 mm

床體積

5 mL

柱內徑

16 mm

基質

highly cross-linked agarose

樣品平均尺寸

85 μm (d₅₀v is the median particle size of the cumulative volume distribution)

cleaning

2-13.7

工作範圍

3-12

容量

≥30 mg binding capacity (humanlgG/ml at 2.4 min residence time)

適合性

suitable for bioprocess medium

儲存溫度

2-8°C

尋找類似的產品? 前往 產品比較指南

相關類別

一般說明

Determined at 10% breakthrough by frontal analysis at a mobile phase velocity of 500 cm/h in a column with a bed height of 20 cm.
HiTrap® MabSelect SuRe columns are prepacked with MabSelect SuRe, a BioProcess medium for purification of monoclonal antibodies from large sample volumes. The novel alkali-tolerant recombinant Protein A ligand allow cleaning-in-place (CIP).

HiTrap® MabSelect columns are prepacked with MabSelect a bioprocess medium for capuring of Mabs from large sample volumes.
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.

特點和優勢

  • Withstands rigorous CIP and sanitization procedures with 0.1 to 0.5 M NaOH.
  • Novel ligand design gives enhanced protease resistance resulting in lower ligand leakage.
  • Oriented coupling of recombinant Protein A to the matrix via an engineered C-terminal cysteine enhances IgG binding capacity.
  • Fewer regulatory concerns due to the total absence of mammalian culture in the ligand production and purification.
  • Prepacked HiTrap® columns for process development, screening of purification conditions, and small-scale purification of Mabs.

分析報告

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

其他說明

1)The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

法律資訊

Free MabSelect SuRe Ligand
"MabSelect SuRe Ligand Restricted License" and "Cys-rProtein A Ligand Restricted License" are protected by the following patents and equivalent patents and patent applications in other countries: US 6,399,750 and EP 1123389. A free, non-transferable limited license to use this product for internal analytical purposes only accompanies the purchase of the product from a Cytiva company and its licensed distributors. Any other use will require a separate license from a Cytiva company.
HiTrap is a registered trademark of Cytiva
MabSelect is a trademark of Cytiva
MabSelect SuRe is a trademark of Cytiva
SuRe is a trademark of Cytiva

象形圖

Flame

訊號詞

Warning

危險聲明

儲存類別代碼

3 - Flammable liquids


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

文章

Desalting at laboratory scale is a well-proven, simple, and fast method that will rapidly remove low molecular weight contaminants at the same time as transferring the sample into the desired buffer in a single step.

在實驗室規模下進行脫鹽是一種行之有效、簡單且快速的方法,可快速去除低分子量雜質,同時只需一個步驟即可將樣品轉移到所需的緩衝液中。

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務