GE17-0404-01

HiTrap® Protein G High Performance

Cytiva 17-0404-01, pack of 5 × 1 mL

同義詞:

Protein purification column

登入查看組織和合約定價


About This Item

分類程式碼代碼:
23151816
NACRES:
NA.56

ligand

recombinant protein G lacking albumin-binding region

包裝

pack of 5 × 1 mL

製造商/商標名

Cytiva 17-0404-01

儲存條件

(20% Ehtanol)
(20% Ethanol)

參數

<4 mL/min flow rate
42 psi

床尺寸

7 mm × 25 mm

床體積

1 mL

柱內徑

7 mm

尺寸

樣品平均尺寸

34 μm

cleaning

2-9

工作範圍

3-9

容量

>1 mg binding capacity (lgG/column)
25 mg binding capacity(human IgG/column)

儲存溫度

2-8°C

相關類別

一般說明

HiTrap® Protein G HP columns are prepacked with Protein G Sepharose High Performance for fast, easy separations of IgG from different species and subclasses.
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.

特點和優勢

  • High binding capacity of 25 mg IgG/mL medium and fast binding kinetics.
  • 34 μm bead size for high performance, high-resolution purifications.
  • Binds broad range of different species and subclasses of IgG.
  • Simple and proven method giving reproducible results.
  • Designed for use with syringe, peristalic pump, or chromatography system.

儲存和穩定性

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

分析報告

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

其他說明

The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

法律資訊

HiTrap is a registered trademark of Cytiva
Sepharose is a trademark of Cytiva

象形圖

Flame

訊號詞

Warning

危險聲明

儲存類別代碼

3 - Flammable liquids


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Lin-Ping Wu et al.
Nature communications, 12(1), 4858-4858 (2021-08-13)
Complement is an enzymatic humoral pattern-recognition defence system of the body. Non-specific deposition of blood biomolecules on nanomedicines triggers complement activation through the alternative pathway, but complement-triggering mechanisms of nanomaterials with dimensions comparable to or smaller than many globular blood

文章

Designing purification methods for antibodies ensures quality and quantity adequacy for research and industrial purposes.

Purify monoclonal or polyclonal IgG from serum, cell culture supernatant or ascitic fluid using the HiTrap Protein G HP from Cytiva, an affinity-exclusion chromatography product containing Sepharose-immobilized Protein G.

This page shows how to purify IgM antibodies by affinity chromatography using HiTrap™ IgM Purification HP.

This page shows how to separate IgG antibodies by affinity chromatography using HiTrap® Protein G HP columns from Cytiva.

查看全部

條款

This page shows how to perform a two-step purification of mouse monoclonal IgG1 using HiTrap® Protein G HP from Cytiva for the capture step.

General instructions for affinity purification using HiTrap columns from Cytiva.

相關內容

This page shows how to perform a two-step purification of mouse monoclonal IgG1 using HiTrap Protein G HP from GE Healthcare for the capture step.

General instructions for affinity purification using HiTrap columns from GE Healthcare.

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務