Epitope mapping has not been conducted. The capture and detection antibodies are Monoclonal Mouse IgG1. The immunogen used is mouse myeloma cell line NS0-derived recombinant human CD163 (aa41-1045), with the accession number CAA80543.
Wybierz wielkość
2700,00 zł
2700,00 zł
Informacje o tej pozycji
sample type cell culture supernatant(s)
sample type urine
sample type serum
Przejdź do
species reactivity
human
packaging
kit of 96 wells (12 strips x 8 wells)
technique(s)
ELISA: suitable, capture ELISA: suitable
input
sample type plasma
sample type cell culture supernatant(s)
sample type urine
sample type serum
assay range
inter-assay cv: <12%
intra-assay cv: <10%
sensitivity: 30 pg/mL
standard curve range: 32.77-8000 pg/mL
detection method
colorimetric
shipped in
wet ice
storage temp.
−20°C
Gene Information
human ... CD163(9332)
Powiązane kategorie
1 of 4
Ta pozycja | |||
|---|---|---|---|
| Gene Information human ... CD163(9332) | Gene Information human ... CD14(929) | Gene Information human ... CD200(4345) | Gene Information human ... DPP4(1803) |
| species reactivity human | species reactivity human | species reactivity human | species reactivity human |
| input sample type plasma | input sample type cell culture supernatant(s) | input sample type urine | input sample type serum |
| assay range inter-assay cv: <12% | assay range inter-assay cv: <12% | assay range inter-assay cv: <12% | assay range inter-assay cv: <12% |
| technique(s) ELISA: suitable, capture ELISA: suitable | technique(s) ELISA: suitable, capture ELISA: suitable | technique(s) ELISA: suitable, capture ELISA: suitable | technique(s) ELISA: suitable, capture ELISA: suitable |
| storage temp. −20°C | storage temp. −20°C | storage temp. −20°C | storage temp. −20°C |
General description
Immunogen
Application
Biochem/physiol Actions
Other Notes
Please type the word sample in the text box provided for lot number.
Elementy zestawu są też dostępne oddzielnie
signalword
Warning
hcodes
pcodes
Hazard Classifications
Met. Corr. 1
Klasa składowania
10 - Combustible liquids
Wybierz jedną z najnowszych wersji:
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Powiązane treści
Instructions
-
Does the CD163 ELISA test for the soluble domain?
1 answer-
Helpful?
-
-
Is it possible to analyze plasma containing EDTA and cerebrospinal fluid (CSF) using the RAB0082?
1 answer-
According to the supplier, Ray Biotech, plasma samples containing EDTA are not suitable for use in this assay due to its chelating property, as noted in the kit manual. Additionally, the assay has not been directly tested with cerebrospinal fluid (CSF), so its compatibility with CSF cannot be confirmed.
Helpful?
-
Active Filters
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej