Przejdź do zawartości
Merck

MAK056

Sigma-Aldrich

Choline/Acetylcholine Quantification Kit

sufficient for 100 colorimetric or fluorometric tests (for choline assay and 50 tests acetylcholine assay)

Synonim(y):

Choline/Acetylcholine Assay Kit

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
12161503
NACRES:
NA.25

zastosowanie

sufficient for 100 colorimetric or fluorometric tests (for choline assay and 50 tests acetylcholine assay)

metoda wykrywania

colorimetric
fluorometric

temp. przechowywania

−20°C

Opis ogólny

Choline is an essential nutrient, commonly grouped with the B complex vitamins, that plays key roles in many biological processes. Choline is a precursor for the synthesis of acetylcholine, a critical neurotransmitter in both the peripheral and central nervous systems.

Zastosowanie

Choline/Acetylcholine Quantification Kit has been used to quantify the amounts of choline and acetylcholine in samples.[1][2]

Przydatność

Suitable for use with cell and tissue culture supernatants as well as serum, plasma, urine, and other biological fluids.

Zasada

In this assay, choline concentration is determined by a coupled enzyme reaction, which results in a colorimetric (570 nm)/fluorometric (λex = 535/λem = 587 nm) product, proportional to the choline present. Acetylcholine levels can be determined by adding acetylcholinesterase to the reaction, which hydrolyzes acetylcholine to choline and acetate.
Ta strona może zawierać tekst przetłumaczony maszynowo.

zastąpiony przez

Piktogramy

Health hazardExclamation mark

Hasło ostrzegawcze

Danger

Zwroty wskazujące rodzaj zagrożenia

Zwroty wskazujące środki ostrożności

Klasyfikacja zagrożeń

Eye Irrit. 2 - Resp. Sens. 1 - Skin Irrit. 2 - STOT SE 3

Organy docelowe

Respiratory system

Kod klasy składowania

10 - Combustible liquids

Temperatura zapłonu (°F)

188.6 °F - closed cup

Temperatura zapłonu (°C)

87 °C - closed cup


Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Compromised epidermal barrier stimulates Harderian gland activity and hypertrophy in ACBP-/-mice
Bek S, et al.
Journal of Lipid Research, jlr-M060780 (2015)
Melis Emanet et al.
Frontiers in bioengineering and biotechnology, 10, 953867-953867 (2022-08-23)
Reactive oxygen species (ROS) are a common hallmark of many degenerative diseases, developing in all those cases where a failure of physiological antioxidant mechanisms occurs (in particular, antioxidant enzymes and the glutathione system), or in case of exposure to an
Elin Rebecka Carlsson et al.
Lipids in health and disease, 18(1), 169-169 (2019-09-07)
Phosphatidylcholine (PC), the most abundant of the phospholipids, has several metabolic functions in organs such as the liver and the intestine, important structural- and signaling functions in biological membranes, and might have a role in the effects of Roux-en-Y gastric
Lara Duran-Trio et al.
Journal of inherited metabolic disease, 45(2), 278-291 (2021-12-23)
Creatine (Cr) is a nitrogenous organic acid and plays roles such as fast phosphate energy buffer to replenish ATP, osmolyte, antioxidant, neuromodulator, and as a compound with anabolic and ergogenic properties in muscle. Cr is taken from the diet or
Effects of Hibernation on the Enteric Nervous System of the Thirteen-lined Ground Squirrels.
Eliades L, et al.
Journal of Undergraduate Research, 1-6 (2014)

Questions

1–5 of 5 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. Does Choline/Acetylcholine Quantitation Kit (Catalog Number MAK056) have reactivity with plasma of dog or canine?

    1 answer
    1. This kit may be suitable with plasma from a canine. Species reactivity is not determined, however, the publications available in the PEER REVIEWED PAPERS section applied this kit to mouse, rat, squirrel, and human samples. There is no reason to suspect canine plasma would not be suitable.

      See the link below to review the publications related to this product:
      https://www.sigmaaldrich.com/search/mak056?focus=papers&page=1&perpage=30&sort=relevance&term=mak056&type=citation_search

      Helpful?

  4. Do I need to prepare two seperate standard sets for free and total choline prepared with different reaction mixes?

    1 answer
    1. While the kit protocol recommends running samples and standards in duplicate, a second set of standards treated with acetylcholinesterase is not required to determine both free and total choline. This can be determined mathematically. See the link below to review the protocol. See page 2 for the free and total choline reaction mix set up. The calculations for Acetylcholine can be found on page 3 in the upper right column.

      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/408/779/mak056bul.pdf

      Helpful?

  5. To prepare choline standards for , fluor. detection0.05 mM standard solution is mixed it with Choline assay buffer to bring the volume to 50 uL. 50 ul of reaction mix will be added to standard wells to bring final volume of 100 ul. Is this correct?

    1 answer
    1. Yes, the final Choline Standard solution is diluted with the Choline Assay buffer to a volume of 50 ul. The 100 ul final volume is comprised of 50 ul of the reaction mix and 50 ul of the standard or sample to be tested. Please read through page two of the product technical bulletin for procedural information:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/408/779/mak056bul.pdf

      Helpful?

Reviews

No rating value

Active Filters

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej